5.3 RESET TO ZERO THE WEIGHING HOOK
To obtain the appropriate weighing results, before starting the weighing process it is necessary to reset to zero the weighing hook.
Unload the weighing hook.
Press the keyboard
if the display has not already been reset to zero.
On the display you are going to see the value 0 (kg) and the LED diode
5.4 TARE
Hang the load to do the tare
The display is going to show the value 0 (kg) and the LED diode is going to be on with the indication NET. The mass of the container is recorded in the
memory of the weighing hook
Hang the material to weigh. The mass that appears in the display corresponds to the net mass.
Once the user has removed the tare, the screen is going to indicate its mass value in negative.
To remove the indication of tare, unload the weighing hook of the crane and press the key
5.5 WEIGHING
Load the weighing hook.
The value of the mass is going to appear immediately. After a correct control of stabilization the LED diode
Overload warning
Avoid any type of overload on the weighing hook which surpasses its maximum load (max), including the load which
implies the tare. If the user does not respect the overload warning, the weighing hook might suffer damages.
The indication –OL-informs of overload, if the load is above the limit values. Download the weighing hook or reduce the
initial load.
5.6 STANDBY MODE
The weighing hook starts the standby mode by pressing the key
At this point, there will be only one segment switched on. To exit from the standby mode the user must press the key
remote control. There is the possibility to choose between the different times of standby: 0, 5, 10 20, 30 minutes. To do so the user must enter the
settings menu and change the parameter F5.
0
will be on.
.
.
USER'S MANUAL SML
which indicates stability will be ON.
of the keyboard or from the
EN
21