6.4.4
[Stroke] Stroke signal output
With every stroke of the pump, the relay output is closed once.
Relay output = potential-free transistor output, load 24 V, DC, 300 mA
6.4.5
[BUS] Internal BUS connection
6.4.6
[Flow] Metering monitoring (e.g. with oval gear meter)
6.4.7
[Diaphragm] Diaphragm breakage monitoring
For the software-side configuration, see
brakeage' on page 118
4 = -
5 = +
6 = GND
7 = CAN L
8 = CAN H
9 = 24 V
53
Assembly and installation
10 = Bus (oval gear meter)
Colour: White
11 = GND
Colour: Blue
12 = Flow monitoring
Colour: Black
13 = 5 volts
Colour: Brown
Ä Chapter 7.10.15 'Diaphragm
417102276 Rev. 3-01.2019