Maintenance Mode - Service Position Of The Pump - [Pump Service.]; Maintenance Mode - Without Access Code - Ecolab EcoAdd Serie Instrucciones De Servicio

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 750
NOTICE!
Damage caused by using incorrect tools!
Damage may occur as a result of using incorrect tools during assembly,
maintenance or troubleshooting. Only use the correct tools.
11.1

Maintenance mode - Service position of the pump - [pump service.]

Before maintenance work is permitted to be performed on the pump, the
pump should be changed to maintenance mode.
The causes the motor and the diaphragm to be reset, simplifying the
maintenance work!
11.1.1

Maintenance mode - WITHOUT access code

Fig. 92: Maintenance mode - WITHOUT access code
Put the pump into maintenance mode:
1.
On the operating screen, press the maintenance symbol ( ,
2.
If the [access code] is not activated
maintenance?'
3.
Cancel maintenance: Press the cancel key
ð The query screen is closed, maintenance mode has not been started and the
operating screen is displayed.
4.
Start maintenance: Press the OK key
ð The pump then puts the motor and the diaphragm into maintenance position.
5.
A prompt screen 'Maintenance: Switch off pump!' is displayed.
6.
Switch off the pump using the 'ON/OFF switch'
To access the maintenance mode, press and hold the displayed
maintenance signal for around 3 seconds.
, the query screen 'pump service' / 'perform
.
.
.
147
Maintenance
or
).
417102276 Rev. 3-01.2019

Publicidad

Tabla de contenido
loading