Silca Tri-Code Manual De Uso página 43

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Operating manual - English
Fig. 31
- close the protective shield. Press START.
- start automatic calibration of the clamp by electrical contact.
the display will show:
At the end of the operation the following message will appear (e.g.):
Press [ENTER] to save the data automatically adjusted.
Attention: if the [STOP] key is pressed the new calibrations will be lost and only the previous calibrations will
remain valid.
- if this is not so, the display will show an error message:
In this case the procedure MUST be repeated, carefully following all the steps described; in particular
check the positioning of the clamp (Ch. 4.4, page 18).
Wrong positioning can throw out the calibration.
Note: the calibrations will be accepted only if the variations remain within a range of -40 or +40 hundredths of a mm
(-0.0157" / +0.0157").
38
tracer point U111
C l a m p : C
D e t e c t i o n
i n p r o g r e s s !
C l a m p : C
X = + 0 4
S a v e d a t a ?
N o = S T O P
E x c e e d e d s e t t i n g
t o l e r a n c e l i m i t !
X = + 4 4
S e e o p e r a t i n g m a n u a l .
Copyright Silca 2006
F2
F1
Y = + 0 1
Ye s = E N T E R
Y = + 0 1
TRI-CODE H.S.
F

Publicidad

Capítulos

Tabla de contenido
loading

Productos relacionados para Silca Tri-Code

Tabla de contenido