Operating manual - English
•
Test 4: X AXIS SENSOR (top carriage)
- the machine display should show OFF with the carriage moved all the way to the right.
- the machine display should show ON with the carriage moved all the way to the left.
Note: if the ON/OFF transition is nor made, contact Silca's Technical Assistance Dept.
•
Test 5: Y AXIS SENSOR (bottom carriage)
- the machine display should show ON when the carriage is drawn away from the machine towards
the operator.
- the machine display should show OFF when the carriage is pushed all the way in towards the
machine.
Note: if the ON/OFF transition is nor made, contact Silca's Technical Assistance Dept.
•
Test 6: MICRO CARTER
Raise or lower the safety shield and check on the display that the indication goes from OFF to ON.
ON = safety shield down; OFF = safety shield up.
Note: if the ON/OFF transition is nor made, contact Silca's Technical Assistance Dept.
•
Test 7: ELECTRIC CONTACT
Use any metal conductor to create a connection between the cutter and the clamp, checking that the
machine display shows first OFF then ON.
The same procedure applies to the decoder.
Note: if the ON/OFF transition is nor made, contact Silca's Technical Assistance Dept.
•
Test 8: DIAL LOCK
Check the state of the dial by moving the lever (N) and checking on the display that the indication goes
from OFF to ON. ON = lever locked; OFF = lever released.
Note: if the ON/OFF transition is nor made, contact Silca's Technical Assistance Dept.
4 X S E N S O R
P r e s s a r r o w s k e y s
t o m o v e a x i s .
S t a t u s : O F F
5 Y S E N S O R
P r e s s a r r o w s k e y s
t o m o v e a x i s .
S t a t u s : O F F
6 S H I E L D M I C R O
O p e n & c l o s e
s h i e l d .
S t a t u s : O N
7 E L E C T R I C C O N T A C T
M a k e a c o n t a c t
C U T T E R
T R A C E R
S t a t . : O N
S t a t . : O F F
8 D I A L L O C K L E V E R
C l o s e a n d o p e n
t h e l o c k i n g l e v e r
S t a t u s : O N
Copyright Silca 2006
TRI-CODE H.S.
49