Operating manual - English
CHECK
FAULT
Display shows
Check whether
message
the fan on the
'TEMPERATURE
back of the key-
ALARM, turn the
cutting machine
machine off".
is working:
Display shows
message 'CUTTER
MOTOR ALARM, check
Fuse F1".
The top X axis carriage
moves to the left or right
and bumps against the
machine end of run.
The bottom Y axis
carriage moves towards
the operator or the
machine face and
bumps against the end
of run.
Fig. 53
70
Not
a) fan faulty or badly wired
working
b) faulty electronic control board (see Ch. 7.4, page 73)
Working
a) faulty electronic control board (see Ch. 7.4, page 73)
a) fuse F1 on the electronic control board cut out (see Ch. 7.3, page 72).
b) cutter protective cover microswitch cut out or disconnected (see Ch. 7.10, page 79 and
Ch. 7.11, page 79).
c) cutter motor wiring disconnected.
d) internal fault on the electronic control board (see Ch. 7.4, page 73).
Use test No 5 (Ch. 5.7.2, page 48) to check operation of the sensor.
Check the fuse F4 (fig. 56, page 72) on the electronic control board.
Check the X axis connecting cable (J1) (fig. 67, page 78).
electronic control board faulty.
Use test No 6 (Ch. 5.7.2, page 48) to check operation of the sensor.
Check the fuse F4 (fig. 56, page 72) on the electronic control board.
electronic control board faulty.