General; Technical Description - Wilo Economy-MHI 2 Serie Instrucciones De Instalación Y Funcionamiento

Ocultar thumbs Ver también para Economy-MHI 2 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 26
ENGLISH

1. General

Installation and service by qualified personnel only
1.1 Applications
The pump is suitable for drinking water, heating water, industrial water,
condensate, water/glycol mixtures up to a ratio of 40% glycol as well
as other liquids free from mineral oil and without abrasives or long-
fibred substances.
The main areas of use are in water supply installations, as a booster
pump, as a boiler feed pump, in industrial circulation systems, in pro-
cess technology, in cooling water systems, in fire extinguishers and in
washing and sprinkler installations.
Approval from the manufacturer must be obtained beforehand if corro-
sive chemicals are to be pumped.

1.2 Technical description

1.2.1 Performance and electrical data
AC voltage:
Rotary current voltage:
Pump
Model
A
1~230 V 3~400 V 1~230 V 3~400 V 1~230 V 3~400 V 1~230 V 3~400 V
MHI
202
205
203
205
204
253
205
253
206
277
402
205
403
205
404
253
405
253
406
277
802
217
803
217
804
277
805
277
1602
237
1603
237
1604
282
When ordering spare parts, please give all the information on the rating plate.
8
1 ~ 230 V (± 10 %) / 50Hz or
3 ~ 230 / 400 V (± 10 %) / 50 Hz;
B
C
88
88
375
88
88
375
88
88
423
88
88
423
104
104
472
88
88
375
88
88
375
88
88
423
104
104
448
137
104
511
88
88
387
104
88
412
104
104
472
-
104
-
-
103,5
-
-
103,5
-
-
136,5
-
Motor power:
Maximum current:
Fluid temperature:
Max. permissible working pressure: 10 bar,
Max. permissible inlet pressure:
Max. ambient temperature:
Protective system:
Other voltages/frequencies and material properties are optional and/or
available on request.
When pumping viscous fluids (e.g. water/glycol mixtures) adjust the
pump data to allow for the higher viscosity.
Only use branded glycol mixtures with corrosion inhibitors and follow
the manufacturers instructions.
For dimensions see table and Fig. 3.
Pump unit
Dimensions
D
mm
375
216
192
375
216
192
423
216
192
423
216
192
472
224
206
375
216
192
375
216
192
423
216
192
448
224
206
472
239
206
387
216
192
387
224
192
472
224
206
472
-
206
432
-
206
432
-
206
515
-
221
see rating plate,
see rating plate,
–15 °C to 110 °C
with gaskets – EPDM
(KTW/WRAS),
–15 °C to 80 °C version with
with gaskets – VITON
6 bar,
40 °C,
IP 54.
E
F
90
90
Rp1
90
90
Rp1
90
90
Rp1
90
90
Rp1
90
90
Rp1
90
90
Rp1
1
/
4
90
90
Rp1
1
/
4
90
90
Rp1
1
/
4
1
90
90
Rp1
/
4
100
90
Rp1
1
/
4
90
90
Rp1
1
/
2
1
90
90
Rp1
/
2
90
90
Rp1
1
/
2
-
90
Rp1
1
/
2
-
90
Rp2
-
90
Rp2
-
100
Rp2
G
H
110
Rp1
110
Rp1
158
Rp1
158
Rp1
182
Rp1
110
Rp1
110
Rp1
158
Rp1
158
Rp1
182
Rp1
122
Rp1
1
/
4
1
122
Rp1
/
4
182
Rp1
1
/
4
182
Rp1
1
/
4
1
138
Rp1
/
2
1
138
Rp1
/
2
183
Rp1
1
/
2

Publicidad

Tabla de contenido
loading

Tabla de contenido