Notes on operation with direct current
G
Travel function: Forwards – Stop – Reverse.
G
Light change.
G
A filtered direct voltage is required for operation.
Operating systems with pulse duration control are
therefore unsuitable.
G
Minimum voltage: 7 – 8 Volt =.
G
This locomotive model comes with an analogue
interface plug. When running exclusively in ana-
logue direct current mode (e.g. with controllers
that do not supply filtered direct voltage), it may be
advantageous to remove the installed multi-train
decoder and mount the interface plug in its place.
Instead of disassembling the decoder, the decoder
plug should only be unplugged if this bare plug
cannot cause a short circuit.
40
Notes on the DCC multi-train system
G
Set address ex works: 03.
G
The maximum achievable speed is about 0.3 m/s
to 0.35 m/s.
G
Driving operation: Forwards – Stop – Reverse with
load regulation.
G
Speed levels: 14 speed levels preset in DCC ope-
ration; 28 or 128 speed levels are detected and
set automatically.
G
Function:
– F0/light function: Light on/off
– F1: Operating noise on/off
– F2: Noise of a whistle on/off
– F3: Noise of a bell on/off
– F4: Driver's cab light on/off
– F5: Noise of an injector on/off
– F6: Minimises the set starting and braking delay