Replacement Parts; Disposal Note; Programme Table - Grohe Europlus E 36 239 Manual De Instalación

Ocultar thumbs Ver también para Europlus E 36 239:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 13
V. Remove and clean flow straightener (13 960), see fold-
out page II.
Assemble in reverse order.

Replacement parts

see fold-out page II (* = special accessories)

Programme table

The infrared electronics provide seven preset programmes for selection.
Programme
1
Temporary shutoff*
2
Automatic flushing*
Flush interval
Flush duration
Usage-dependent
Usage-independent
Duration of thermal disinfection
1
*
Cleaning mode can be activated when temporary shutoff is activated. In cleaning mode, water flow is not started for
3 minutes even if an object is detected.
2
*
Automatic flushing serves to ensure water hygiene in the event of long-term non-utilisation of the fitting. Flushing is initiated
for a duration of 5 minutes after 24 hours (usage-independent) or for a duration of 1 or 5 or 10 minutes after 72 hours
(usage-dependent) after the fitting was last used.
Safety note:
Ensure free draining in the case of activated automatic flushing.
Fault / Cause / Remedy
Fault
Cause
Water not flowing
• Battery without contact
• Water supply interrupted
• Filter upstream of solenoid valve blocked
• Solenoid valve defective
• Plug-in connector of solenoid valve without
contact
• Battery discharged
• Cleaning mode activated
Water flowing
• Solenoid valve defective
continuously
• Thermal disinfection activated
Undesired water
• Sensor system detection zone set too high
flow
for local conditions
• Automatic flushing activated
Flow rate too low
• Flow straightener dirty
• Filter upstream of solenoid valve dirty
• Filters in the union connection set blocked
• Water supply restricted
Water temperature
• Thermostat not adjusted to local pressure
too high or too
• Non-return valve defective
low
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.

Disposal note

Dispose of batteries in accordance with national
regulations.
1
2
3
Active
Active
Active
Inactive
Active
Active
-
24 h
24 h
-
5 min
5 min
-
x
-
x
3,5 min
3,5 min
11 min
Remedy
- Clean contacts
- Open shut-off valves
- Clean or replace filter
- Replace solenoid valve
- Check plug-in connector
- Replace battery
- Deactivate cleaning mode or wait 3 minutes
- Replace solenoid valve
- Wait 3.5 or 11 minutes
- Reduce range using remote control (special
accessory, prod. no.: 36 206)
- Wait 1 - 10 minutes
- Clean or replace flow straightener
- Clean filter
- Clean or replace filters
- Check supply lines, open shut-off valves
- Adjust thermostat
- Replace non-return valve
4
5
6
Active
Active
Inactive
Active
Active
Inactive
72 h
72 h
-
10 min
1 min
-
x
x
-
-
3,5 min
3,5 min
3,5 min
7
Inactive
Active
72 h
5 min
x
3,5 min
6

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Europlus e 36 240

Tabla de contenido