TEChNiCAL dATA
Contol unit supply
Power supply
Output supply
Power maximum motor
Output supply accessories
Protection level
Operating temp.
Radio receiver
Rolling code transmitters supported
Wire connections shown in Fig. 1 are described hereunder:
Terminals
Function
L/N
Power supply
GND
GND
ANT/SHIELD
Antenna
+12V
COMMON
PP
Step-by-Step
PED
PEDESTRIAN
STOP
STOP
PHO
PHOT O
PHA
PHOT C
+12V
COMMON
BAR/BAR
SENSITIVE EDGE
SCA
Service light
RX 2° Ch
PHOTO TEST
24Vac
24Vac
ENC1
ENCODER
SWC
SWC
SWO
SWO
24 Vdc
230 Vac 50/60 Hz or 115Vac 50/60Hz according to the version
1 motor 230Vac
280 W
24Vac 500mA max.
IP54
-20°C / +50°C
built in 433,92 MHz confgurabile (rolling-code or programmable + rolling-code)
64 rolling-code
CP.BULL8 om CoNTRoL UNiT

WiRE diAGRAm

description
CP.BULL8 OM: Input, 230Vac 50Hz (L-Phase/N-Neutral)
CP.BULL8 OM 115: Input, 115Vac 60Hz (L-Phase/N-Neutral)
Earth (compulsory)
Connection antenna to the built-in receiver
(ANT-signal/SHIELD-screen).
Common for control inputs.
Input, step-by-step push-button (N.O. contact)
Presettable as Input, OPEN with OPCL logics.
Input, pedestrian push-button (N.O. contact). It controls the partial opening, configurable
through parameter TPED. At end of TCA time (if activated), closure control signal is sent.
Presettable as Input, CLOSE with OPCL logics.
Input, STOP push-button (N.C. contact)
Input, (N.C. contact) for safety devices (e.g. photocells).
During closure: if the contact is opened, the motor stops. With OPCL logics, when the
photocell is no longer obscured, the motor reversion occurs (gate opens).
During opening: if the contact is opened, the motor stops. with OPCL logics When the
photocell is no longer obscured, the motor restarts opening.
Input, (N.C. contact) for safety devices (e.g. photocells).
During closure: it can be preset by PHCL logics.
During opening: it can be preset by PHCL logics.
Common for control inputs.
Input, sensitive edge contact
Resistive edge: Jumper "DAS" closed
Mechanical edge: Jumper "DAS" open
If the edge is activated, the gate stops and a movement reversion occurs for about 3 sec.
If the edge is not in use: Jumper "DAS" open, jumper between terminals BAR/BAR.
Free, N.O. contact. Presettable as:
-
SCA (open gate indicator lamp): open contact when gate is closed, fast flashing light
when gate is closing, slow flashing light when gate is opening and closed contact
when gate is open. See wire diagram, Fig.2).
(Logics 2CH:OFF, SERL:OFF, TST1:OFF, TST2:OFF);
-
Timed service light (see SERL logics and diagram in Fig.2);
-
Output, second radio channel (see 2CH logics and diagram in Fig.2);
-
PHOTO TEST to power the transmitters of photocells in TEST mode (see TST1, TST2
logics and diagram in Fig.3).
Output, power supply of accessories, 24Vac/500mA max
Connector for connection of anti-crash sensor (ENCODER)
Input, CLOSE limit switch (N.C. contact)
Input, OPEN limit switch (N.C. contact)