The intervention threshold of the anti-crashing device (Encoder) during braking is adjusted *.
SEAR
99:maximum sensitivity - 0: minimum sensitivity
TLS
Activated only with SERL:ON Logic. The activation time of the service light is adjusted.
The force of the motor brake is adjusted.
Ibra
0: disabled braking - 1:minimum braking - 99: maximum braking
* WARNiNG: An incorrect setting of these parameters may cause danger.
mENU
The automatic closure is enabled or disabled
TCA
On: enabled automatic closure
Off: disabled automatic closure
The multi-flat function is enabled or disabled.
On: enabled multi-flat function. The P.P. (Step-by-step) impulse or the impulse of the
IbL
transmitter have no effect in the opening phase.
Off: disabled multi-flat function.
The rapid closure is enabled or disabled
On: rapid closure is enabled. When the gate is open or moving, the photocell activation causes
SCL
the automatic closure of the gate after 3 s. It is activated only with TCA:ON
Off: rapid closure is disabled.
The operating mode of "P.P. Push button" and of the transmitter are selected.
PP
On: Operation: OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
Forewarning flashing light enabled or disabled.
On: enabled forewarning flashing light. The flashing light is activated 3 s before the starting
PRE
of the motor.
Off: disabled forewarning flashing light.
During the TCA time, the blinker is enabled or disabled.
LTCA
On: Activated blinker.
Off: De-activated blinker.
The OPEN input mode is selected. When activated the logic function OPCL must be ON.
On: OPEN input to be connected to a timer. The opening and closing operations are per-
CLOC
formed depending on the timing set on the timer.
(CLOSED contact - open gate. OPEN contact - normal operation).
Off: OPEN input with OPEN function.
Enables or disables the hold to run function. When activated the logic function OPCL must
be ON.
htr
On: hold to run function enabled.
During operation, the OPEN/CLOSE push-buttons must be kept pressed for all the stroke.
Off: Automatic functioning.
During the TCA phase, the PP and PED controls are enabled or disabled. When activated the
logic function OPCL must be OFF.
IBCA
On: PP and PED controls are disabled.
Off: PP and PED controls are enabled.
The Encoder is enabled or disabled.
ENC
On: Encoder enabled.
Off: Encoder disabled.
The TRIAC test is enabled or disabled.
tri
On: Test on: if TRIAC is faulty the motor does not start.
Off: no test on TRIAC is performed.
The code programmable transmitters is enabled or disabled.
On: Radio receiver enabled only for rolling-code transmitters.
CVAR
Off: Receiver enabled for rolling-code and programmable code transmitters (self-learning and
Dip Switch).
The second radio channel is enabled or disabled on terminal AUX.
On: AUX output, preset as second radio channel.
2CH
SERL, TST1 and TST2 logics must be preset on OFF.
Off: AUX output can be set as SCA, or by SERL, TST1 and TST2 logics.
The service light function is enabled or disabled on AUX output.
On: At each operation the contact is closed for the time preset with TLS parameter. TST1 and
SERL
TST2 logics must be set on OFF.
For the light control, use an auxiliary relay.
Off: AUX output can be preset as SCA, or by 2CH, TST1 and TST2 logics.
Please comply with regulations in force!
LOGIC (LOG)
FUNCTioN
0-99-(0%)
1-240-(60s)
0-99-(50%)
oN-oFF-
mEmo
(default)
(ON)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(ON)
(OFF)
(OFF)
(OFF)
(OFF)