jbc advanced AM 6500 Serie Manual De Instrucciones página 13

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

ENGLISH
These
tips
are
specially designed to
clean the pads.
Ref. 5600-001
A ø
5600
A ø (mm)
B ø (mm)
max. pin ø
(mm)
B ø
Change of desoldering tip
This operation should be done while the tip is
hot, at a minimum temperature of 250°C, so that
any tin left inside is in molten state.
- Unscrew the tip to be replaced, with the aid
of the spanner supplied.
- Fit the new tip, and tighten up with the
spanner to achieve a good air tightness.
DESOLDERING TIPS
5600-011
5600-012
5600-002
001 / 011
002 / 012
1.4
1.8
0.6
0.8
0.4
0.6
Ref. 0780550
5600-013
5600-003
5600-004
003 / 013
004
2.7
3.2
1
1.3
0.8
1.1
To empty the solder tin deposit and change
the filter
For this, the lid needs to be unscrewed and first
the tin deposit and then its spiral must be
removed to clean the inner part of the deposit
with a brush.
-
The condition of the filter must be checked
and replaced if dirty or damaged.
-
The deposit needs to be inserted with
spiral filter put into place. Then the whole
must be closed by screwing the lid shut.
12
5600-005
5600-006
005
006
3.4
4.2
1.6
2
1.4
1.7
Filter Ref.0780840
Spiral
Deposit
Ref. 0786640
5600-007
007
4.8
2.5
2.3
Lid
Brush

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Advanced serieAdvanced ar 5800

Tabla de contenido