4.1.5.1 Cable Bending Radius
R
min
ø d
The following minimum values apply for encoders with cable
outlet (R
):
min
R
min
Fixed installation
75 [2.95]
Flexible use
110 [4.33]
4.2 Electrical Installation
4.2.1 General Information for the Connection
ATTENTION
Destruction of the device
Before connecting or disconnecting the signal cable, always
disconnect the power supply and secure it against switching
on again.
54 - EN
General safety instructions
Make sure that the whole plant remains switched off during
the electrical installation.
• Make sure that the operating voltage is switched on or off
simultaneously for the device and the downstream device.
52104843
Other operating instructions applicable for the installa-
tion
To connect the device, refer to the corresponding operating
and safety instructions of the external drive system / evalu-
ation system / control.
When assembling a mating connector, comply with the in-
structions attached to the connector.
No open cable wires
Connect all required cable wires / connectors before commis-
sioning. Insulate individually all unused ends of the output
signals to avoid short-circuits.
• Electrostatic discharges at the contacts of the connector or
at the cable ends could damage or destroy the device. Take
appropriate precautionary measures.
NOTICE
NOTICE
NOTICE
BA Sendix® 58xxFS2 / 58xxFS3 - R60049.0009 - 05