6.

TROUBLESHOOTING

FAULTS
1. The system cuts out
abnormally.
2. The system switches on
with interruptions.
3. The
motor
discontinuously and the
water is flowing very
slowly.
4. The motor is working
correctly but it does not
switch
off,
remaining
operating for a long time.
5. The motor does not start.
6. The motor is working
with a loud knocking
noise, or it is buzzing
and not working.
7. For FEKALIFT 200-A:
cloudy water returning
into the shower.
1.

TECHNICAL DATA AND LIMITATIONS OF USE

The FEKALIFT 300-A system is a small lifting station with extremely compact dimensions, suitable
ONLY for suspended toilets, to be installed behind ordinary wall modules, fig.A-B page 62
The system is used for the disposal of waste water from a toilet and possibly from other plumbing
equipment.
The system is NOT intended for use in public and/or commercial settings.
2.

INSTALLATION

FEKALIFT 300-A is a built-in system. It may be fitted only and exclusively by a qualified, specialised
technician.
The small lifting station is equipped with retaining devices which prevent the unit becoming accidentally
detached from the toilet.
2.1

System assembly

To assembly the Fekalift 300-A system follow fig.C-D page 62
An inspection/maintenance hatch must be provided with ventilation slots in the frame
having at least the following dimensions: L=400 mm H= 400 mm!
CHECKS (possible causes)
The
system
pumping too long (thermal safety
switch).
Error in the control system.
The connected plumbing systems
are not sealed (valves, etc.).
The check valve is not closing
properly.
works
The ventilation hole in the cover
is blocked.
Discharge too high or too long or
presence of too many bends in the
pipes with consequent loss of
pressure.
The bottom of the pump is
clogged.
The system is not connected to
the power mains.
The power socket is damaged.
There is a problem with the motor
or with the control system.
The motor is blocked by a foreign
body.
There is a problem with the motor
or with the control system.
The shower is too low with
respect to the Fekalift system.
The check valves of the side
inlets are clogged.

FEKALIFT 300-A LIFTING STATION

ENGLISH
has
continued
8
REMEDIES
Take the plug out of the
socket. Wait an hour and
reconnect the system.
Otherwise contact an
authorised customer service
centre.
Check the system.
Clean or change the check
valve.
Clean the ventilation hole.
Check the system.
Otherwise contact an
authorised customer service
centre.
Connect the system to the
power mains.
Otherwise
contact
authorised customer service
centre.
Remove the foreign body.
Otherwise
contact
authorised customer service
centre.
Check the system installation.
Clean the check valves from
the outside, otherwise contact
an
authorised
service centre
an
an
customer