Electrical Connection; Connector S32/Cable Connection; Connector S115 - Balluff Micropulse BTL7-A/E501-M Serie Manual Del Usuario

Ocultar thumbs Ver también para Micropulse BTL7-A/E501-M Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

BTL7-A/E501-M_ _ _ _-A/B/Y/Z(8)-S32/S115/S140/KA_ _/FA_ _
Micropulse Transducer - Rod Style
4
Installation and connection (continued)
Supporting rod made of non-magnetizable material
Fig. 4-8:
Example 2, transducer installed with supporting rod
4.4.1

Connector S32/cable connection

S32
Cable color
Pin
1
YE yellow
2
GY gray
3
PK pink
4
RD red
5
GN green
6
BU blue
7
BN brown
8
WH white
Tab. 4-2:
Connection assignment BTL7...S32/cable
4.4.2

Connector S115

S115
Pin
-A501
1
2
3
10 to 0 V
4
5
0 to 10 V
6
7
8
Tab. 4-3:
Connection assignment BTL7...S115
Unassigned leads can be connected to the GND on the controller side but not to the shield.
1)
Factory setting, can be freely configured with the PC software.
2)
Reference potential for supply voltage and EMC-GND.
3)
www.balluff.com
Magnet
(e.g. BTL-P-1028-15R)
BTL7-... interface
-A501
Not used
4 to 20 mA
1)
0 V
10 to 0 V
(output 2)
20 to 4 mA
2)
La (communication line)
0 to 10 V
(output 1)
2)
GND
3)
10 to 30 V
Lb (communication line)
BTL7-... interface
0 V (pin 3)
0 V (pin 5)
(output 2)
20 to 4 mA
2)
La (communication line)
(output 1)
4 to 20 mA
2)
GND
3)
10 to 30 V
Lb (communication line)
4.4

Electrical connection

Depending on the model, the electrical connection is made
using a cable or a connector.
The connection or pin assignments for the respective
version can be found in Tab. 4-2 to Tab. 4-4.
Note the information on shielding and cable
routing on page 12.
-E501
(output 1)
2)
Fig. 4-9:
(output 2)
2)
Not used
1)
-E501
Fig. 4-10: Pin assignment of S115
(output 2)
2)
(output 1)
2)
Pin assignment of S32
connector (view of connector
pins of transducer)
connector (view of connector
pins of transducer)
english