ELIMINATING FAULTS
MALFUNCTION
Pressure at the manometer rises
to more than 40 bars.
Mortar spraying machine does
not pump enough coating
material.
If the defect is not caused by one of the above-mentioned faults, have the defect eliminated by the WAGNER customer service.
24
POSSIBLE CAUSE
Viscosity of the coating material too
high.
Mortar hose diameter too small.
Mortar hose is too long.
Coating material "plug" in the mortar
hose. Mortar hose not prerinsed with
cellulose paste.
Convey capacity selected too low.
Mortar hose diameter too small.
Stator worn.
Texture tip too small.
ELIMINATION
Dilute the coating material.
Use a mortar hose with a larger diameter.
Use a shorter mortar hose.
Depressurize the mortar hose – set the selector
switch to "R" (reverse).
Pump the coating material back into the container.
The mortar hose must be pressureless.
Watch the manometer ––> 0 bar.
Wear safety goggles.
Decouple mortar hose and rinse with water hose.
When the plug has been removed, fill cellulose paste
in the mortar hose. Couple the mortar hose back on.
Set the volume regulator higher.
Use a mortar hose with a larger diameter.
Mount a new stator, if necessary, also a new rotor.
Attention: Spray on pump sliding means.
Select a larger texture tip.
Rule of thumb: Granular size x 3 ––> Tip size
PowrMax