TRANSPORTATION / COMMISSIONING
5
TRANSPORTATION
5.1
MOVING
Wind power cable around handle and remove the hose.
Put away the nozzles and other small objects in the storage
compartment.
Push or pull the PowrMax 605 by the handle.
Make sure that 2 people are available to carry the
device on stairs.
5.2
TRANSPORT USING A CRANE (FIG. 4)
For attaching points for the straps or rope (not wire cable) see
figure.
5.3
TRANSPORTATION IN VEHICLE
Secure the unit in the vehicle by means of suitable fasteners.
To avoid material residues leaking from the
i
machine, clean the device in advance or lock the
mortar connection.
12
6
COMMISSIONING
6.1
INSTALLATION LOCATION
Position mortar spraying machine in a level position to prevent
it from sliding away.
6.1.1
CONNECTION TO MAINS POWER SUPPLY/
EXTENSION CABLE
Connection to the mains network only via a special feeding
point, for example via a distribution board for construction
sites, with residual current protective device with INF ≤ 30 mA.
Lay the device supply cable so that there is no
danger of stumbling.
Protect against damage, for example against
being driven over.
Min. wire cross-section 3 x 2.5 mm2. Unroll the
extension cable completely. Ensure that the
coupling pieces and plugs are free of damage.
Attention
•
Before connecting the unit to the mains supply, ensure
that the line voltage matches that specified on the rating
plate.
6.2
INITIAL STARTING-UP
6.2.1
SCOPE OF SUPPLY
The machine is supplied by the manufacturer in the following
individual components:
•
Complete basic machine comprising drive unit, control
unit, receptacle and transport frame with wheels
•
Stator
•
Hose package
•
Spray lance
•
Pump sliding means
•
Tool box with nozzles, cleaning accessories,...