7 SPECIFICATIONS
This chapter describes the technical specifications (electric and mechanical).
Mechanical Data
Working range [m]
Height protection [mm]
Number of beams
Step increasing module
Nº beams / height [mm]
Distance between beams [mm]
Minimum detectable object [mm]
Fixation
Vibration absorption
Working temperature
Storage temperature
Degree of protection
Optical Data
Effective aperture angle
Working centroid wavelength
IR Frequency modulation
Immunity external light
Electrical Data
Rated voltage [U
]
N
Consumption
Output element
Output logic
Output current [I
]
OUT
Output voltage [V
]
OUT
Drop output voltage [V
]
DO
Output load
Life time
Compliance
Directives
Standards
Safety level
LSP14
0.2 ÷ 5.0
200 ÷ 800
20 ÷ 80
10 / 100
10
14
By clamp / corner bracket
By special rubber nitric cushion
-10 ÷ 50 ºC and 95 % humidity
-20 ÷ 70 ºC and 95 % humidity
IP65
LSP14
≤ 5° rad @ 3 m
Infrared 940 nm
65 KHz
1,500 lux
LSP14
+ 24 V DC ±15 %
≤ 2.5 W
Dual channel OSSD
PNP / NC
ON SATE ≤ 150 mA @ V
OUT
OFF SATE ≤ 1.5 mA @ V
OUT
ON SATE = U
- V
N
DO
OFF SATE ≤ V
DO
≤ 2 V DC
Resistive ≤ 160 Ω
Inductive ≤ 20 mH
Capacitive ≤ 200 nF
≤ 10 years
LSP14
2014/35/EC: Low voltage
2004/108/EC: EMC
2006/42/EC: Machinery
2011/65/EU: RoHS
IEC 61508-1
ISO 13849-1
IEC 61496-1
IEC 61496-2
IEC 61000
IEC 60529
SIL 3
PL e
Type 4
Specifications
LSP29
LSP300
0.2 ÷ 7.0
5.0 ÷ 30.0
200 ÷ 1600
600 ÷ 1200
10 ÷ 80
3 ÷ 5
5 / 100
1 / 300
20
29
LSP29
LSP300
≤ 5° rad @ 5 m
LSP29
LSP300
LSP29
LSP300
300
9
LSP | 32