3.1
Disconnect electrical power to the branch circuit at the
circuit breaker or fuse box before attempting to install the
ceiling fan hanger bracket on the outlet box.
3.2
Remove the hanger ball by loosening the setscrew in the
hanger ball until the ball falls freely down the downrod
(Figure 1).
Remove the pin from the downrod, then remove the
hanger ball.
Retain the pin and hanger ball for reinstallation in
NOTE: Do not loosen the screw holding the green
Step 3.8.
ground wire.
3.3
Separate, untwist and unkink the two 80" motor leads.
Route the 80" black and white motor leads through the
downrod (Figure 2).
3. Ceiling Fan Assembly
5
WARNING
!
Turning off wall switch is not sufficient. To avoid possible
electrical shock, be sure electricity is turned off at the
main fuse box before wiring. All wiring must be in
accordance with National and Local codes and the ceiling
fan must be properly grounded as a precaution against
possible electrical shock.
PIN
Figure 1
TWO 80" MOTOR
LEADS (UNTWISTED)
Figure 2
Please contact 1-800-654-3545 for further assistance
HANGER BALL
SETSCREW
(LOOSENED)
6" DOWNROD
6" DOWNROD
emersonfans.com
E.T.L. Model No.: CF985