VE1100 Series PIRs
Installation instructions
Installation instructions
EN
Introduction
The VE1100/VE1100AM family is made up of PIR/PIR-AM motion
sensors. They have a patented mirror, pyro and signal processing
technology.
Installation guidelines
The technology used in these detectors resists false alarm
hazards. However, avoid potential causes of instability such as
(see Fig. !):
Direct sunlight on the detector.
Heat sources within the detector field of view.
Strong draughts onto the detector.
Animals within the detector field of view.
Objects within 50 cm (20 in.) of the anti-masking (AM)
detector.
Obscuring the detector field of view with large objects, such
as furniture.
Installing two detectors facing each other and less than
50 cm (20 in.) apart (only AM detectors).

Installing the detector

Lift off the custom insert and remove the screw (see Fig. ",
1.
step 1).
2.
Using a screwdriver, carefully prise open the detector (see
Fig. ", steps 2 and 3).
3.
Fix the base to the wall between 1.8 m and 3.0 m (5.9 and
9.8 ft.) from the floor. For flat mounting use a minimum of two
screws (DIN 7998) in positions A. For corner-mounting use
screws in positions B or C (Fig. #). To install a pry-off tamper,
use position A or C.
Wire the detector (see Figs. # and &).
4.
5.
Select the desired jumper and DIP switch settings (see
Fig. %).
See section
information.
6.
Remove the blinders and add the stickers, if required (see
Fig. ' for an example).
7.
For ceiling-mount applications that require a 90° coverage
use the SB01 swivel-mount bracket.
8.
Close the cover.
9.
Insert the screw and place the custom insert.
10. For EN 50131 grade 3 installations, do not use mounting
position B.
e detector
Setting th

Jumper settings

See figure % for the jumper locations in the detector.
J1: Not used
J3 and J4: Dual loop setting
This sets the alarm and tamper relays. It allows you to connect the
detector to any control panel. Use jumpers 3 and 4. See
picture &.
Use Remote Test (RT) to test the detector from the control panel.
The detector will activate the Alarm relay if the test result is
positive, and the AM relay if the test result is negative.
J6: Polarity setting of the control voltage (CV)
On: "Active High" provides the standard GE Security logic with
"Active High" logic to enable Walk Test (WT), Day/Night (D/N)
and Remote Test (RT) inputs.
Off: "Active Low" provides "Active Low" logic to enable Walk Test
(WT), Day/Night (D/N) and Remote Test (RT) inputs.
Active High
Ex-factory
DIP switch setting
Ex-factory
SW 1: When to signal AM (anti-masking) or TF (technical fault)
output
On: Signals AM or TF only when the system is in Day mode (ex-
factory).
Off: Always signals AM or TF during Day and Night mode.
SW 2: AM sensitivity
On: Selects a higher level of AM sensitivity. AM relay reacts within
6 seconds.
Off: Selects the standard AM sensitivity. AM relay reacts within
12 seconds (ex-factory).
Setting
the
detector
for
Active Low
SW 3: Resetting the AM/TF output
The system will only reset an AM alarm if it has ensured that the
cause of the AM alarm has been removed. If the AM circuitry
cannot return to its original reference levels, then either the
detector is still masked or possibly has been damaged. The owner
should then visually check that the detector is still fully functional.
On: Resets the AM or TF status 40 seconds after a PIR alarm.
Off: Resets the AM or TF status after a PIR alarm when the
system is in Day and Walk Test status. The yellow LED will
blink quickly. When the system is in Night status, the yellow
LED will turn off and the system is reset (ex-factory).
SW 4: Signaling AM or TF output
On: Signals AM on both the AM and Alarm relays. Signals TF on
the AM relay only (EN 50131).
Off: Signals AM and TF on the AM relay (ex-factory).
SW 5: Setting LEDs
On: Enables both LEDs on the detector at all times (ex-factory).
Off: Puts both LEDs under the control of the Walk Test and
Day/Night input. This activates the memory feature of the
detector.

LED indication

Continuously on
Fast blinking (4 Hz)
PIR
Red
LED
Start up
Low voltage
PIR intruder
alarm
PIR/AM
Red
LED
Start up
more
Low voltage
PIR intruder
alarm
Latched PIR
(Memory)
AM alarm
After AM
reset
Technical
fault
* Depends on the setting of the DIP switch SW4.

Technical specifications

Detector
Signal processing
Range
Optical
Memory
Input power
Peak-to-peak ripple
Detector start-up time
Normal current (mA)
Current in Alarm (mA)
Max. current (LED on)
(mA)
Mounting height
Target speed range
Alarm (NC) / Tamper
relay characteristic
Pry-off tamper
AM relay characteristic
PIR Alarm time
Operating temperature
Dimensions (H x W x D)
Relative humidity
Weight
IP/IK rating
Normal blinking (1 Hz)
Yellow
Alarm
AM relay To reset
LED
relay
Closed
Open
(Alarm)
Open
(Alarm)
Yellow
Alarm
AM relay To reset
LED
relay
Closed
Closed
Open
Open
(Alarm)
(Alarm)
Open
(Alarm)
Open*
Open
(Alarm)
(Alarm)
Open
(Alarm)
VE1120
PIR
V2E
20 m
11 high-density mirror curtains
Yes
9 to 15 VDC (12 V nominal)
2 V (at 12 VDC)
25 s
4.4
1.2
11
Min. 1.8 m, max. 3.0 m (Min. 5.90 ft., max.
9.84 ft.)
30 cm/s to 3 m/s
20 cm/s to 3 m/s
(1 ft./s to 10 ft./s)
(0.65 ft./s to 10 ft./s)
80 mA, 30 VDC
Optional
80 mA at 30 VDC
3 s
-10 to +55°C (14 to 130°F)
125 × 55 × 60 mm
125 × 65 × 60 mm
(4.92 x 2.16 x 2.36 in.)
(4.92 x 2.6 x 2.36 in.)
Max. 95%
150 g
IP30 IK02
3
Automatically
after 25 s
Apply correct
voltage
Automatically
after 3 s
Automatically
after 60 s
Apply correct
voltage
Automatically
after 3 s
Switch toNight
mode
See DIP
switch 3
Switch to
Night mode
Do a successful
walk test
VE1120AM
PIR + AM
60 s
10
3.8
24
80 mA, 30 VDC