Step
Description
5.
Calibrate the measuring system (optional)
S If necessary, calibrate the measuring system
(see WinPISA manual or system manual).
Move the axis manually (optional)
6.
S Check the functioning of the controller and the effective
ness of the software end positions (see WinPISA manual
or system manual).
7.
Enter the program
Enter a program in order to move the axes.
e.g.:
Set the operating mode and the starting program
8.
Recommendation (for first commissioning):
S Define the test program as starting program A.
S Deactivate starting program B (starting pr. B=***).
S Set the operating mode Start/Stop (easier test
possibilities).
9.
Test the program in Debug mode or in Continuous run
Prerequisites:
The program must be in the program memory
The axis and application data must be set and the project
must be loaded into the SPC200.
The operating mode Start/Stop and the starting program
must be set.
There must be a 1−signal at ENABLE and STOP.
22
N000 G01 X80 FX50
N001 G01 X140 FX50
N002 M30
;pos. 80 or adapt.
;pos. 140 or adapt.
;program end