5. Technical data

Nominal voltage
Nominal current input
Nominal power input
Mains frequency
Mains plug
Fuse rating
Core bit diameter range
Speeds under load
1st speed
2nd speed
3rd speed
Torque
1st speed
2nd speed
3rd speed
Weight (motor unit)
Supply cord length
Core bit connection end
Core bit connection end
Core bit connection end
Motor cooling
Minimum flow rate
Protection class
Motor overheating protection
Mechanical overload protection
5.1 Noise and vibration
Typical A-weighted noise levels of the machine are:
– Noise (pressure) level:
Ear protection must be worn.
Typical exposure of the hand / arm to vibration is less than 2.5 m/s
Right of technical modifications reserved!
7. Assembling the system components
7.1 Mounting the baseplate taper on the baseplate
2
1
3
4
7.3 Fitting the water collector holder to the baseplate taper
1
2
3
4
Printed: 07.07.2013 | Doc-Nr: PUB / 5069604 / 000 / 00
400 V / 3 ~
7.5 A
4.1 kW
50 Hz
16 A
16 A
80–500 mm
160 r.p.m.
340 r.pm.
510 r.p.m.
Max. 300 Nm
Max. 200 Nm
Max. 150 Nm
24 kg
5 m
DD-C-BU Hilti patent
" UNC
DD-C-BS
1
1
/
4
DD-C-Pixie
Water cooling
3.3 l/min
IP55
Direct via motor windings
Slip clutch
77 dB (A)
2
.
1. Baseplate
2. Baseplate taper
3. Mounting screws (4)
4. Wrench
(supplied with the
baseplate)
1. Baseplate taper
2. Screw
3. Holder
4. 8 mm AF wrench
(supplied with the holder)
6. Electrical and mechanical safety
6.1 Electrical safety
The ground fault interrupter incorporated in jobsite mains supply circuits pro-
vides protection from faults in the insulation of the motor unit, supply cord
and extension cables. The machine's earth / ground conductor protects the
operator in case of accidentally drilling into live cables. The built-in undervol-
tage trip prevents the machine from restarting of its own accord when power
returns after an interruption in the power supply.
6.2 Protection against overheating
The motor is protected from the effects of sustained overload by a tempera-
ture sensor built into the motor windings. A warning lamp incorporated in the
ON/OFF switch indicates when activation of this safety circuit is imminent.
6.3 Mechanical safety
The slip clutch incorporated in the gearing section protects the insert tool
and motor unit from damage in case the core bit suddenly sticks.
7.2 Fitting the wheel assembly to the baseplate
4
3
2
1
7.4 Changing the chuck
3
4
1. Baseplate
2. Wheel
3. Screw
4. 19 mm AF wrench
1. Drive shaft
2. Chuck
3. Screws (2)
4. 6 mm AF wrench
(supplied with the chuck)
1