• Estimated charge time
Battery capacity
Charge timing 0% >>> 90%
*Lead battery corresponding : A lithium battery has a better starting performance (CCA) than a lead battery. That's why some lithium battery
manufacturers indicate the battery lead equivalent (EqPb) which corresponds to the capacity of a lead-acid battery with the same starting perfor-
mance. For instance, a LFP battery of 10 Ah will have the same starting performance as a lead-acid battery of about 30 Ah.
• Protections :
The GYSFLASH 1.12 Lithium has comprehensive safety features to protect it against short-circuits and polarity rever-
sals. It has an anti-spark feature which prevents sparks whilst connecting the device to the battery. This charger has
double insulation and is safe to use with the battery in situ as it will protect the vehicle's on-board electronics.
The GYSFLASH 1.12 Lithium is fitted with an integrated temperature probe that ensures that the charging current is adapted to the
ambient temprature to prevent internal electronics' overheating.

TROUBLESHOOTING

Troubleshooting
1
The indicator
blinks rapidly.
2
The indicator
blinks slowly.
3
The indicator
is on.
4
The indicator
blinks.
WARRANTY
The warranty covers faulty workmanship for 2 years from the date of purchase (parts and labour).
The warranty does not cover:
• Transit damage.
• Normal wear of parts (eg. : cables, clamps, etc..).
• Damages due to misuse (power supply error, dropping of equipment, disassembling).
• Environment related failures (pollution, rust, dust).
In case of failure, return the unit to your distributor together with:
- The proof of purchase (receipt etc ...)
- A description of the fault reported
GYSFLASH 1.12 LITHIUM
1 Ah
5 Ah
(3 Ah EqPb*)
(15 Ah EqPb*)
1 h 30
4 h 30
Causes
• Polarity reversal
• Battery voltage is too high
Battery is faulty or has a very low
voltage.
• Charge failure, battery non recove-
rable.
• Thermal protection.
Charger in sleep mode.
10 Ah
20 Ah
(30 Ah EqPb*)
(60 Ah EqPb*)
8 h 30
16 h
• Check that the clamps are properly connected.
• Check that it is a 12V battery.
Change the battery.
• Change the battery and restart a charge.
• Ambient temperature is too high (>50°C), cool
the room and let the charger cool down.
Connect a battery to the charger to exit sleep
mode.
EN
Solutions