1
Step
: Analysis
Analyses the battery state (charge level, polarity inversion,
wrong battery...)
2
Step
: Recovery (0.5A)
Damaged elements recovery due to an extended deep
discharge algorithm
3
Step
: Test
Sulfated battery test
4
Étape
: Desulfation (15.8V)
Battery desulfation algorithm.
• Estimated charge time
Battery capacity
Charging time 20% >>> 80%
If the motorbike is fitted with a 12V plug, the GYSFLASH 1.12 can charge the battery via this plug with the CAN-BUS
system, without switching the dashboard on. In this setup, connect the cigarette lighter adapter on the charger and on
the motorbike's 12V socket then follow the «start up » procedure on the previous page. In certain cases, it is possible
that the charge will only start 2 minutes after performing the connections.
• Protections :
The GYSFLASH 1.12 has several features to protect it against short-circuits or polarity inversion. It has an anti-spark
feature which prevents sparks whilst connecting the device to the battery. This charger has double insulation and is
compatible with vehicle's onboard electronics.
The GYSFLASH 1.12 is fitted with an integrated temperature probe that ensures that the charging current is adapted to the
ambient temperature to prevent internal electronics' overheating.
TROUBLESHOOTING
Symptoms
1
The indicator
blinks rapidly.
2
The indicator
blinks slowly.
3
The indicator
is on.
4
The indicator
blinks.
GYSFLASH 1.12
Step
Fast charge with maximum current that can reach 80% charge
level.
Step
Constant voltage charge to reach a 100% charge level.
Step
Maintains battery charge level at its maximum.
2Ah
10Ah
20Ah
2h
6h
12h
Causes
• Polarity inversion
• Battery voltage is too high
Battery is faulty or has a very low
voltage.
• Charge failure, battery non recove-
rable.
• Thermal protection.
Charger in sleep mode.
5
: Charge (1A)
6
: Absorption (14.5V)
7
: Floating charge (13.6V)
32Ah
19h
• Check that the clamps are properly connected.
• Check that it is a 12V battery.
Change the battery.
• Change the battery and restart a charge.
• Ambient temperature is too high (>50°C), cool
the room and let the charger cool down.
Connect a battery to the charger to exit sleep
mode.
EN
Remedies
7