2. Open all spray nozzles/taps.
3. Run pump until remaining water is
expelled.
4. Disconnect inlet and outlet tubes.
5. Run pump briefly to confirm that
water has been expelled.
6. Spray nozzles/taps shall remain
open and pump fittings shall
remain disconnected until tempe-
ratures are above freezing
Never start a frozen pump. Even if it is
drained it might contain a small amount
of frozen water that locks the rotor.
Service instructions
(see page 42-43)
Change of Switch (pos A)
1. Remove the screws (28) and then
remove the complete switch
including diaphragm (19).
2. Remove the cables (30 and 31) from
the motor cable and power source.
3. Take the new switch and attach the
cables to motor and power source.
4. Locate the new diaphragm (19) and
then the new complete switch.
Change of Diaphragm kit (pos B)
1. Remove the screws (18) with a
Torx #20 tool (a standard Phillips
type screw #20 tool). (Pos 18 screws
should be fitted to the through holes
which can be seen on the backside of
the motor end bell).
2. Separate the pump assembly from
motor.
3. Remove the screws (17) with a Torx
#20 tool (a standard Phillips type
screw #20 tool).
4. Hold the black pumpbody (14)
towards the ground. Carefully
remove the diaphragm kit (B) from
pump body (14). Ensuring that pos
10-14 still remains together with
pump body (14).
5. Locate the diaphragm kit into pump
body (14) incl pos 10-14 and mount
the five short screws (17) into the
threaded holes in the motor flange.
Original instructions
6. Mount the complete pumphead kit
7. Assemble the remaining long screws
Change of complete Pump kit (pos C)
1. Remove the screws (28) and then
2. Remove the cables pos (30 and 31)
3. Remove the screws (18) with a Torx
4. Separate the pump assembly from
5. Mount the complete pumphead kit
6. Assemble the long screws (18) which
7. Locate the diaphragm (19) and then
.
Accessories
See page 44
Waste handling & material recycling
At the products end of life, please dispose of
the product according to applicable law. Where
applicable, please disassemble the product and
recycle the parts material.
onto the motor coupling flange
taking notice to fit the slot in cam (5)
in right position against motor shaft
and the three slots on motor end
bell.
(18) which will hold the motor/pump
unit together. (pos 18 screws should
be fitted to the through holes that
can be seen on the backside of the
motor end bell).
remove complete switch including
diaphragm (19).
from the motor cable and power
source.
#20 tool (a standard Phillips type
screw #20 tool). (pos 18 screws has a
through hole on the backside of the
motor end bell).
the motor.
onto the motor coupling flange
taking notice to fit the slot in cam
(5) in right position against motor
shaft and the three slots on the
motor end bell.
will hold the motor/pump unit
together. (pos 18 screws should be
fitted to the through holes that can
be seen on the backside of the motor
end bell).
the complete switch.