Sterling 2375 Serie Guia De Instalacion página 7

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

42" (106.7 cm)
9-7/8"
(25.1 cm)
3. Locate the Drain Pipe and Shower Receptor
Locate the Drain Pipe
NOTE: The drain system is designed for a 2" (5.1 cm) drain pipe that is flush with the subfloor.
Determine the location of the drain pipe using the dimensions illustrated.
Cut a 5" (12.7 cm) to 5-1/2" (14 cm) hole in the subfloor. This will provide adequate clearance for
the drain system.
Install the drain pipe. Verify the drain pipe is self-supporting and strapped down.
Locate the Shower Receptor
NOTE: The subfloor under the shower receptor must be level. Adjust the subfloor with leveling compound
as needed. Do not shim.
Place the shower receptor firmly against the two adjacent walls. Ensure the drain pipe is aligned
with the precut hole in the shower receptor.
Verify the shower receptor is flush against the studs.
If the shower receptor is not flush against the studs, use shims between the nailing flange and stud
wall as needed.
Sterling
Sectional View for 2375 Base
42" (106.7 cm)
Threshold
Solid Floor
9-7/8"
(25.1 cm)
42"
(106.7 cm)
Wall Surround
Shim (Optional)
Ledger Board
Drain
9-7/8"
(25.1 cm)
5" (12.7 cm) D.
7
2x4
Stud
5-3/4"
(14.6 cm)
Framed Floor
1100676-2-C

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

1100676 2 c