Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 10

ELECTRICAL CONNECTION

1.
Controls
Contact
1
3
N.O. OPEN
1
4
N.O. CLOSE
1
9
N.C.
STOP
WARNING: Link up all N.C. contacts (if not used) by means of jumpers. The terminal bearing the same number are equivalent. The
given operating and performance features can only be guaranteed with the use of DITEC accessories and safety devices.
2.
Output and accessories
Output
Value
1
+
24V= / 0.5 A
0
-
+BL / -BL
24V= / 2 A
3.
Settings and adjustment
R28 - (Figure 2) Cut the R28 resistance only in the case of two motors being installed in parallel.
Each 906S card fi tted into the 906 panel controls one automatic access fi tted up with one or two geared motors. The 906 control
panel can accommodate up to six 906S cards (only one 906S card is supplied as standard equipment).
Attention: Properly fi t in the cards with panel powered off, whether from 220V mains or battery.
Simultaneous controls for all motors: Maximum drive load = 3 motors + 3 locks WITHOUT batteries or 6 motors + 6 locks WITH
batteries.
4.
ELECTRIC BOARD INSTALLATION AND STARTING
4.1
Firmly secure the electric board.
4.2
Drill a hole on the underside of the electric cabinet for cable routing. If cables are accessible, secure by means of appropriate
cable fi ttings (not provided).
4.3
Keep power leads at least 8 mm from control and motor leads at terminal strip connections (eventually using clamps).
4.4
Make a jumper between stop (1-9).
WARNING: the operations regarding point 3.5 are without safety devices.
4.5
Power and check that door operates properly by sending several open, close.
4.6
Remove jumpers, connect stop (1-9) and check for proper operation.
4.7
Connect any accessories and check their function.
4.8
Re-close the container by means of the 4 screws.
All right reserved
All data and specifi cations have been drawn up and checked with the greatest care. The manufacturer cannot however take any
responsibility for eventual errors, ommisions or incomplete data due to technical or illustrative purposes.
Function
It starts the opening operation.
It starts the closing operation.
It stops any movement. When 1-9 contact is reset, the door stays stopped
until the next open or close command is given.
Accessories power supply. Output for power external accessories.
Lock device. Output for power lock device.
Description
Description
5
GB
0906 - IP1443

Publicidad

Tabla de contenido
loading