Siemens SIMATIC NET SCALANCE X-300 Manual De Configuración página 436

Ocultar thumbs Ver también para SIMATIC NET SCALANCE X-300:
Tabla de contenido

Publicidad

Anexo D
D.1 Mensajes de error del SCALANCE X300 / X400
Avisos cuando se produce un error
Observer: RM test frame timeout on both ring
ports.
Observer stopped recovering because of too
many (<número de errores>) repeated errors.
(Observer needs to be restarted (WBM/CLI)
manually).
Power down on line <ID de la fuente de alimenta-
ción>.
Internal error: <tensión> V power down.
Wrong module <nombre de módulo> on slot
<número de slot> (ID: <ID de módulo>).
C-PLUG not accepted. See System C-PLUG
mask for details.
C-PLUG interface unmounted. Restart required.
C-PLUG missing.
Media module for ring <número de puerto> mis-
sing.
DIP switch <nombre del interruptor> changed.
Restart required.
DIP switch <nombre del interruptor> differs from
C-PLUG. Restart required.
Internal error(s) and/or exception(s) occurred.
Device boot up incomplete.
RM <dirección MAC> lost.
Media module for standby <número de puerto>
missing.
PNIO fault - please use STEP 7 for diagnostics.
PNIO connection established.
Severe module change detected. Restart re-
quired.
DIP switch settings manipulated ...
→ Redundancy will be started after next restart.
Authentication status on <número de puerto>:
FAILED! Reason: %s.
Standby <observer | partner> freezes current
state <active | passive> because <master |
slave> <dirección MAC> gone.
Default route is stored in hardware.
Non-recoverable error on ring %u: RM receives
test frames from only one ring port.
Non-recoverable error on ring %u: Another re-
dundancy manager detected.
Last MRP manager in ring %d won't stop on ring
ports <número de puerto> and <número de puer-
to> (danger of network loops).
436
Avisos tras solucionar un error
Observer: RM test frames received.
Observer restarted because of user command.
Power up on line <ID de la fuente de alimenta-
ción>.
Internal error gone: <tensión> V power is back.
Wrong module <nombre de módulo> on slot
<número de slot> removed.
C-PLUG accepted.
C-PLUG interface mounted.
C-PLUG detected.
Media module for ring <número de puerto> de-
tected.
DIP switch <nombre del interruptor> set back to
original state.
DIP switch <nombre del interruptor> set back to
state saved on C-PLUG.
Internal error(s) and/or exception(s) confirmed.
Device boot up complete.
RM <dirección MAC> detected.
Media module for standby <número de puerto>
detected.
PNIO fault - gone.
PNIO connection terminated.
Severe module change reverted.
DIP switch settings reset ...
→ Redundancy mode will not change after next
restart.
Authentication status on <número de puerto>:
OK. Reason: %s.
Unfreeze standby state <active | passive> be-
cause partner <dirección MAC> became visible.
Default route no longer in hardware.
Non-recoverable error gone on ring %u: RM
receives test frames from both ring ports.
Non-recoverable error gone on ring %u: Other
redundancy manager gone.
MRP ring %d manager may stop now (no danger
of network loops anymore).
Manual de configuración, 02/2018, C79000-G8978-C187-31
SCALANCE X-300 / X-400