Reduction Of Emf In The Workplace; Limitations Of Use; Controls: Position And Functions; Front Panel - Rear Panel - Oerlikon MINIARC 3.2Gi Instrucciones De Seguridad, Empleo Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 9
CHECK GAS DELIVERY; TURN GAS CYLINDER KNOB TO
REGULATE FLOW .
NB: The electric welding arc is struck by lightly touching the work-
piece with the electrode (Scratch start).
CAUTION: WHEN WORKING OUTDOORS OR IN WINDY CON-
DITIONS PROTECT THE FLOW OF SHIELDING GAS OR IT
MAY BE DISPERSED WITH RESULTING LACK OF PROTEC-
TION FOR THE WELD.
2.5

REDUCTION OF EMF IN THE WORKPLACE

ELECTROMAGNETIC FIELD CAN AFFECT PACEMAKER OP-
ERATION.
High current flowing through the welding cables during the weld-
ing operation causes a generation of electromagnetic fields. To
reduce the intensity of these fileds in the workplace (if required),
use the following procedures:
1.
Keep the cables arranged close together by twisting or taping
them.
2.
Arrange cables to one side and away from the operator.
3.
Do not coil or drape cables around your body.
4.
Keep welding power source and cables as far away from op-
erator as practical.
5.
Connect earth clamp to workpiece as close to the welded
area as possible.
2.6

LIMITATIONS OF USE

This equipment is designed for use under standard operational
and environment conditions. To ensure its full operational capabil-
ity; to avoid the danger and possibility of equipment's damage
please always follow these recommendations:
1.
Do not use the equipment in areas with extremaly low or high
ambient temperature.
2.
Do not use the equipment in areas with presence of danger-
ous, flamable and/or explosive gases.
3.
Avoid the contact of equipment with water; do not use the
equipment outdoors when it is rainig and/or snowing.
4.
Never use the welding power source for pipe thawing; this
equipment is designed solely for welding.
3.0

CONTROLS: POSITION AND FUNCTIONS

3.1

FRONT PANEL - REAR PANEL

Picture 1.
2
3
6
5 5
1.
Connect the earth lead to the work piece to the negative ter-
minal (-) (Ref. 6 - Picture 1 Page 4.)
2.
Connect the torch lead to the positive terminal (+) (Ref. 5 -
Picture 1 Page 4.).
CONTROLS: POSITION AND FUNCTIONS
1
4 EN
ENSURE THAT THESE CONNECTIONS ARE WELL TIGHT-
ENED TO AVOID POWER LOSS AND OVERHEATING.
3.
Use control knob (Ref. 2 - Picture 1 Page 4.) to regulate
welding current.
4.
Illuminated switch (Ref. 1 - Picture 1 Page 4.) must be ON
(lamp light) before welding operations can be started.
5.
Illumination of the transparent LED (Ref. 3 - Picture 1 Page
4.) on the front panel indicates a possible states.
Possible states of the equipment indicated by the front panel bi-
color LED:
LED COLOR
GREEN-YELLOW
GREEN
YELLOW (CONTINUOS)
YELLOW (FLASHING)
4.0

MAINTENANCE

DISCONNECT POWER BEFORE MAINTENANCE. SERVICE
MORE OFTEN DURING SEVERE CONDITIONS.
Every three (3) months, perform the operations below:
1.
Replace unreadable labels.
2.
Clean and tighten weld teminals.
3.
Repair or replace cracked cables and cords.
Every six (6) months, perform the operation below:
Blow out the inside of the unit. Increase frequency of clean-
ing when operating in dirty or dusty conditions.
EN
STATUS INDICATED
Initialization status
Power On / Ready
Thermal Alarm / Overheating
Abnormal Status / Contact Ser-
vice

Publicidad

Tabla de contenido
loading

Tabla de contenido