Sundstrom SR 500 EX Instrucciones De Uso página 37

Ocultar thumbs Ver también para SR 500 EX:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
•.. Triangle.that.lights.up.with.a.red.light.if.the.air.
flow.should.cease.or.if.the.filters.are.clogged.
•.. Battery.symbol.that.lights.up.with.a.yellow.light.
when.the.battery.capacity.is.low.
•.. Initiates.an.alarm.by.sound/light.signals.in.the.event.
of.an.obstruction.in.the.air.flow.
•.. Equipped.with.automatic.air.flow.control.
•.. Can.be.used.together.with.a.hood,.visor.or.full.face.
mask.
Air flow rates
On.normal.operation,.the.fan.delivers.at.least.175.l/
min,.and.on.boosted.operation,.at.least.225.l/min..The.
automatic.flow.control.system.of.the.fan.unit.maintains.
these.flows.constant.throughout.the.operating.time.
Warning system/alarm signals
• In the event of air flow obstructions
. If.the.air.flow.should.drop.below.the.preselected.
value.(175.or.225.l/min),.this.is.indicated.in.the.
following.way:
•.. A.pulsating.sound.signal.will.be.heard.
•.. The.red.warning.triangle.of.the.display.will.
flash.
Action: Immediately.interrupt.the.work,.leave.the.area,.
and.inspect.the.equipment.
• If the particle filters are clogged
. If.the.particle.filters.are.clogged,.this.is.indicated.in.
the.following.way:
•.. A.continuous.sound.signal.will.be.heard.for.five.
seconds.
•.. The.red.warning.triangle.in.the.display.will.
flash.
. The.warning.triangle.will.flash.continuously,.
whereas.the.sound.signal.will.be.repeated.at.
intervals.of.80.seconds.
Action:.Immediately.interrupt.the.work,.leave.the.area.
and.change.the.filter..
N.B..No.signal.is.activated.when.the.gas.filters.are.
saturated..For.particulars.of.changing.the.gas.filters,.
see.under.2.4.Filters.and.the.user.instructions.
supplied.with.the.filters.
• If the battery capacity is low
. If.the.battery.capacity.has.dropped.to.about.5.%.of.
the.original.charge,.this.is.indicated.as.follows:
•.. A.sound.signal.will.be.repeated.twice.at.
intervals.of.two.seconds.
•.. The.yellow.battery.symbol.of.the.display.will.
flash.
. The.battery.symbol.will.flash.continuously,.whereas.
the.sound.signal.is.repeated.at.intervals.of.30.
seconds.until.about.one.minute.remains.before.the.
battery.would.be.fully.discharged..The.sound.signal.
then.changes.to.an.intermittent.signal.
Action:.Immediately.interrupt.the.work,.leave.the.area.
and.change/charge.the.battery..
Filters
See.2.4.Filters
Breathing hose
The.breathing.hose.is.not.included.with.the.fan.unit.
but.is.supplied.with.the.relevant.head.top.
Head top
The.choice.of.head.top.depends.on.the.working.
environment,.work.intensity.and.the.required.
protection.factor..The.following.head.tops.are.available.
for.the..
SR.500.EX:
•.. Class.TH3.Hood,.model.number.SR.520.
•.. Class.TH3.hood,.model.number.SR.530.
•.. Class.TH3.Hood,.model.number.SR.561.
•.. Class.TH3.Hood,.model.number.SR.562.
•.. Class.TH3.visor,.model.number.SR.540.EX.
•.. Class.TM3.full.face.mask,.model.number.SR.200.
•. Class.TH3.helmet.with.visor,.model.number..
SR.580.
1.3 Warnings/limitations
Warnings
The.equipment.must.not.be.used.
•.. In.the.power-off.state..In.this.abnormal.situation.a.
rapid.build-up.of.carbon.dioxide.and.depletion.of.
oxygen.may.occur.in.the.head.top.and.no.
protection.is.given.
•.. If.the.surrounding.air.does.not.have.a.normal.
oxygen.content.
•.. If.the.pollutants.are.unknown.
•.. In.environments.that.are.immediately.dangerous.to.
life.and.health.(IDLH).
•.. With.oxygen.or.oxygen-enriched.air.
•.. If.you.find.it.difficult.to.breathe.
•.. If.you.can.smell.or.taste.the.pollutants.
•.. If.you.experience.dizziness,.nausea.or.other.
discomfort.
Limitations
•. The.SR.500.EX.ATEX/IECEx.approval.applies.only.
when.all.components.are.ATEX/IECEx.approved..
Therefore,.when.purchasing.spare.parts.and.
accessories,.always.make.sure.of.their.proper.
approval.if.the.equipment.is.to.be.used.in.explosive.
atmospheres.
•. The.peel-offs.for.the.head.tops.are.not..ATEX/
IECEx.approved.and.must.not.be.used.if.the.
equipment.is.to.be.used.in.explosive.atmospheres.
•. The.battery.must.not.be.charged.in.explosive.
atmospheres..
•.. The.SR.500.EX.must.always.be.used.with.two.
particle.filters.or.two.combined.filters.
•.. If.the.user.is.exposed.to.very.high.work.intensity,.a.
partial.vacuum.may.occur.in.the.head.top.during.
the.inhalation.phase,.which.may.involve.the.risk.of.
leakage.into.the.head.top.
•.. The.protection.factor.may.be.reduced.if.the.
equipment.is.used.in.surroundings.in.which.high.
wind.speeds.occur.
•.. Be.aware.that.the.breathing.hose.might.make.a.
loop.and.get.caught.up.by.something.in.your.
surrounding.
•.. Never.lift.or.carry.the.equipment.by.the.breathing.
hose.
•.. The.filters.must.not.be.fitted.directly.to.the.head.
top.
•.. Only.use.Sundström.filters.
•.. The.user.should.take.care.not.to.confuse.the.
markings.on.a.filter.to.standards.other.than.EN.
12941:1998.and.EN.12942:1998.with.classification.
of.the.SR.500.EX.fan.unit.when.used.with.this.filter.