Sundstrom SR 500 EX Instrucciones De Uso página 39

Ocultar thumbs Ver también para SR 500 EX:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
Warning!
•. Never.charge.the.battery.in.an.explosive.
atmosphere.
•.. The.battery.may.be.charged.only.with.the.genuine.
Sundström.charger.No..R06-2003.
•.. Charger.No..R06-2003.may.be.used.only.for.
charging.the.batteries.for.the.SR.500.EX.
•.. The.charger.is.designed.only.for.use.indoors.
•.. The.charger.must.not.be.covered.while.it.is.in.use.
•.. The.charger.must.be.protected.against.moisture.
•.. Never.short.circuit.the.battery.
•.. Never.try.to.dismantle.the.battery.
•.. Never.expose.the.battery.to.a.naked.flame..There.is.
risk.of.explosion/fire.
b) Belt
The.belt.consists.of.two.identical.halves.that.can.be.
fitted.to.the.rear.of.the.fan.unit.without.tools..Proceed.
as.follows:
•.. Place.the.fan.upside.down..
•.. Insert.the.three.tongues.of.the.belt.half.into.the.slot.
in.the.fan..The.folded.end.of.the.strap.should.face.
upwards..Study.the.illustration.carefully.to.ensure.
that.the.belt.will.not.end.up.upside.down.or.back.to.
front..Fig..4.
•.. Press.down.the.three.lips.locking.the.belt.half..Fig..
5.
•.. Proceed.in.the.same.way.with.other.half.of.the.belt.
•.. The.length.of.the.belt.can.easily.be.adjusted.by.
pulling.in.or.slackening.the.strap.ends.
c) Breathing hose
Hoods
The.breathing.hose.is.already.fitted.to.the.hoods.
Proceed.as.follows:
•.. Check.that.the.O-ring.of.the.hose.is.in.place..Fig.6.
•.. Connect.the.hose.to.the.fan.unit.and.turn.it.
clockwise.about.1/8.of.a.turn..Fig..7.
•.. Check.that.the.hose.is.firmly.secured.
Face shield SR 540 EX
When.using.the.SR.540.EX,.the.face.shield.and.
breathing.hose.are.delivered.separately.
Proceed.as.follows:
One.end.of.the.hose.is.provided.with.a.flat.gasket.and.
the.other.with.an.O-ring..Connect.the.end.with.the.
gasket.to.the.face.shield.
•.. Check.that.the.O-ring.of.the.hose.is.in.place..Fig.6.
•.. Connect.the.hose.to.the.fan.unit.and.turn.it.
clockwise.about.1/8.of.a.turn..Fig..7.
•.. Check.that.the.hose.is.firmly.secured.
Full face mask SR 200
When.using.the.SR.200.full.face.mask.for.the.fan.unit,.
the.mask.and.breathing.hose.are.delivered.separately.
Proceed.as.follows:
•.. One.end.of.the.hose.is.provided.with.a.threaded.
adapter..Connect.the.adapter.to.the.filter.thread.of.
the.mask..Fig..8.
•.. Connect.the.other.end.to.the.fan.unit.as.described.
above.
•.. Connect.the.hose.to.the.fan.unit.and.turn.it.
clockwise.about.1/8.of.a.turn..Fig..7.
•.. Check.that.the.hose.is.firmly.secured.
d) Particle filters/combined filters
Two.filters.or.combined.filters.of.the.same.type.and.
class.must.always.be.used.at.the.same.time..Proceed.
as.follows:
1. Particle filter SR 510
•.. Check.that.the.gaskets.in.the.filter.mounting.of.the.
fan.unit.are.in.place.and.are.in.good.condition..Fig..
9.
•.. Snap.the.particle.filter.onto.the.filter.adapter..Do.not.
press.onto.the.centre.of.the.filter.-.it.might.damage.
the.filter.paper..Fig..10.
•.. Screw.the.adapter.into.the.filter.mounting.so.far.
that.the.adapter.will.be.in.contact.with.the.gasket..
Then.turn.it.about.1/8.turn.further.in.order.to.ensure.
a.good.seal..Fig..11.
•.. Fit.one.pre-filter.into.the.filter.holder..Fig..12.
•.. Press.the.filter.holder.onto.the.particle.filter..Fig..13.
2. Particle filter SR 710
•.. Check.that.the.gaskets.in.the.filter.mounting.of.the.
fan.unit.are.in.place.and.are.in.good.condition..Fig..
9.
•.. Screw.the.filter.into.the.filter.mounting.so.far.that.
the.adapter.will.be.in.contact.with.the.gasket..Then.
turn.it.about.1/8.of.a.turn.further.in.order.to.ensure.
a.good.seal..Fig..11.
•.. Fit.one.pre-filter.into.the.filter.holder..Fig..12.
•.. Press.the.filter.holder.onto.the.particle.filter..Fig..13.
3. Combined filters
•.. Check.that.the.gaskets.in.the.filter.mounting.of.the.
fan.unit.are.in.place.and.are.in.good.condition..Fig..
9.
•.. Snap.the.particle.filter.onto.the.gas.filter..The.
arrows.on.the.particle.filter.must.point.towards.the.
gas.filter..Do.not.press.onto.the.centre.of.the.filter.
-.it.might.damage.the.filter.paper..Fig..14.
•.. Screw.the.combined.filter.into.the.filter.mounting.
until.it.is.in.contact.with.the.gasket..Then.turn.it.
about.1/8.turn.further.to.ensure.a.good.seal..Fig..
15.
•.. Fit.a.pre-filter.into.filter.holder..Fig..12.
•.. Press.the.pre-filter.holder.onto.the.combined.filter..
Fig..16.
Filter.SR.599.is.a.combined.gas.filter.and.particle.filter.
and.is.screwed.directly.into.the.filter.mounting.of.the.
fan..Proceed.as.described.above.
2.6 Operation/performance
•.. Start.the.fan.by.pressing.the.control.button..Fig..17.
•.. After.the.button.has.been.pressed,.a.programmed.
test.will.be.run.on.the.fan.unit,.during.which.the.
symbols.on.the.display.will.light.up.and.the.sound.
signal.will.sound.twice..Fig..18.
•.. After.the.internal.test,.all.symbols.will.be.extin-
guished.except.the.small.green.fan.symbol..This.
indicates.normal.operating.status.with.a.flow.of.at.
least.175.l/min.
•.. If.the.button.is.pressed.again,.boosted.operating.
status.will.be.activated,.with.a.flow.at.least.225.l/
min..This.is.indicated.by.the.larger.green.fan.
symbol.lighting.up.
•.. To.revert.to.normal.operation,.press.the.control.
button.once.again.
•.. To.switch.off.the.fan.unit,.keep.the.control.button.
depressed.for.about.two.seconds.
39

Publicidad

Tabla de contenido
loading

Tabla de contenido