6 Putting into operation
6.1 Setting up the torch
1
2
10
1
Gas nozzle
2
Powder nozzle
3
Alignment gauge
4
Torch body
Fig. 4
Overview of the wear parts
EN - 12
3
9
8
5
Centring ceramics
6
Tungsten electrode
7
Back cap
CAUTION
Risk of injury
Puncture or cut-in wounds may be caused by the wire electrode.
• Keep your hands out of the danger zone.
• Wear the correct protective gloves.
NOTICE
• The poor current and heat transfer of loosely fitted plasma nozzles will
result in irreparable damage to the torch.
®
ABIPLAS
WELD 100/150 POWDER W
4
5
8
Insulating ring
9
Distributor ring
10 Plasma nozzle
BAL.0086 • 2020-12-17
6
7