Key P:
_ Program key
_ To choose if the temperature is displayed in °C
or in °F after switching on the first handpiece
_ To select the preset temperatures P1–P3 for
each handpiece (continuously)
The factory-default temperatures for both hand-
pieces are:
P1
70 °C
P2
100 °C
P3
130 °C
How to change temperature settings:
The Smartwax duo also offers the possibility to set
the programs P1-P3 to individual temperatures
as needed.
For this, press P to select the program (P1, P2,
or P3) to be changed.
Use < to lower or > to increase the temperature
to the desired value. Then, press P for about 3
seconds until the display flashes. Now, this tem-
perature is saved and can be chosen later on by
selecting the according program via the program
key P.
How to exchange the tips:
Hold the tip at the cork handle and pull it off. The
modeling tips are firmly attached to the cork handle
in order to prevent that the tip accidentally changes
its position during modeling.
Now, choose the modeling instrument desired and
hold it at the cork handle. Insert it into the hand-
piece until you hear a clicking sound.
The back side of the control unit offers several
receptions to store additional modeling tips.
IMPORTANT: Removing the cork handle exposes
the heating element (9). Therefore, do not touch
the heating element in order not to burn your
fingers!
Waxjet:
Mount the Waxjet onto the handpiece shank in the
same way as any other modeling instrument.
Insert the wax wire between the feeding rollers
(10) until it touches the melting pan. As soon as
the wax starts melting, slowly but continuously
feed forward the wax wire by turning the drive
roll attached at the side (11) in the direction of the
modeling tip.
Do not change the feeding direction of the wax
wire very often or very quickly in order to prevent
bubbles in the wax.
MAINTENANCE
As most of AmannGirrbach's products, Smartwax
duo does not require special maintenance. Just
8
(158 °F)
(212 °F)
(266 °F)
keep it clean.
In general, the cork handle with the modeling tip
is easy to turn on the handpiece shank. If not, check
the cork handle and the heating element for con-
tamination. Do not clean modelling instruments
with sharp objects. Use a cloth or paper towel
instead to wipe it off as long as it is hot; reheat if
necessary.