Installation; Connection To Piping; Terminal Box Position - STA-RITE vx Manual Del Producto

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PIPING ASSEMBLY
incorrect
air locks
Power supply
The power supply mains must have the following characteristics:
- A differential protection
- Voltage and frequency values matching the ones shown on the
machine motor rating plate
- A power output not lower than the value shown on the machine
motor rating plate
- An electromagnetic switch having a fit thermal protection
- A self-balanced thermal relay adjusted on the basis of the actual
absorbed current
- A cut-off switch with protecting fuses
- Cables having a section fit for the current absorbed by the
motor.
Access
Connect the machine in a place that can be easily accessed for
maintenance operations
Support
The machine fastening system can match one of the following
systems:
- The machine can be connected to fixed piping able to keep the
machine in its position.
- The machine can be connected to a pipeline and positioned on
a surface having the characteristics shown in "Product specifi-
cation" paragraph "Foundations"
- The machine can be connected to a pipe line secured by means
of nuts to a surface having the characteristics shown in "Product
specification" paragraph "Foundations"

3.6 Installation

3.6.1 Connection to piping

Machines with oval flanges
Carry out the following operations to connect the machine to
piping:
- Unscrew the screws fastening the counterflanges to the
machines.
- Remove the two counterflanges
- Remove the two gaskets present between counterflanges and
machine base
- Brake the protecting central disks along the marked lines to get
two gaskets with central holes.
- Screw the two counterflanges at the threaded ends of the
piping.
- Position the machine so that the arrows on the base match the
fluid flow direction.
- Position the two circular gaskets between couterflanges and
machine
- Alternatively tighten the screws fastening the counterflanges to
the machine
correct
Machine with round flanges
Carry out the following operations to connect the machine to
piping:
- Fit two counterflanges having a size matching those of the
machine flanges to the pipe ends
- Remove the two protecting caps on the machine flanges
- Position the machine so that the arrows on its base match the
fluid flow direction
- Fit the two circular gaskets between counterflanges and flanges
- Fit the screws in the flange and counterflange holes
- Alternatively tighten the nuts on the screws
Counterflange

3.6.2 Terminal box position

Carry out the following operations to direct the terminal box in the
required position:
- Remove the connection covering grids
- Unscrew the assembly bolts of motor and machine body
- Rotate the motor of 90° or 180° or 270° (in relation to the initial
position)
- Screw the bolts alternatively and in a uniform way
- Refit the connection covering grids
threaded
pipe
machine with
screws
gaskets
counterflange
flow direction
indication
bolt
(screw and nut)
and pipe
caps to be
taken away
gasket
indication of flow
direction
oval flange
screws
threaded
pipe
machine with
round flange
bolt
(screw and nut)
counterflange
and pipe

Publicidad

Capítulos

Tabla de contenido
loading