1 I/O interface
1 I/O interface
Total bus data width: 5 words, 10 byte, 80 bit input/output
Bit
Byte
0
0
1
0
2
0
3
0
4
0
5
0
6
0
7
0
8
1
9
1
10
1
11
1
12
1
13
1
14
1
15
1
16
2
17
2
18
2
19
2
20
2
21
2
22
2
23
2
24
3
25
3
26
3
27
3
28
3
29
3
30
3
31
3
EN - 2
Word
Roboter inputs / MFS-V3 outputs
0
System ready for operation
0
No fault
0
Process active
0
0
Wire is in window 1
0
Wire is in window 2
0
Gas pressure present
0
Wire available
0
Control lead connected
0
No internal nonconformity
0
Program available
0
Wire movement active
0
0
Arc is on (hot wire power source)
0
Hot wire power source ready
0
1
Operating-hours-based maintenance due
1
Delivery-time-based maintenance due
1
Cycle-based maintenance due
1
Delivery-amount-based maintenance due
1
In automatic mode
1
Acknowledge operating mode W1
1
Acknowledge operating mode W2
1
Acknowledge operating mode W4
1
Acknowledge program W1
1
Acknowledge program W2
1
Acknowledge program W4
1
Acknowledge program W8
1
Acknowledge program W16
1
Acknowledge program W32
1
Acknowledge program W64
1
Acknowledge program W128
BUS interface with job selection
Roboter outputs / MFS-V3 inputs
Release process
Acknowledge fault
Start wire forwards
Feed in the wire
Start wire backwards
Hot wire
Gas valve
Air blast valve
Reset operating-hours-based maintenance
warning
Reset delivery-time-based maintenance
warning
Reset cycle-based maintenance warning
Reset delivery-amount-based maintenance
warning
Operating mode W1
Operating mode W2
Operating mode W4
program W1
program W2
program W4
program W8
program W16
program W32
program W64
program W128