Fault
Red LED flashes and
signal tone sounds six
times.
Red LED lights up and
signal tone sounds six
times.
The pressing tool remains
unchanged and no LED
lights up.
18014400405789195-1 © 02-2018
968.400.00.0 (00)
Cause
Stop button was
pressed or pressing
tool was not in
starting position.
Set values for the
pressing jaw have not
been attained.
Pressing tool is
overloaded.
Contamination or
deposits between the
jaw levers or in the
pressing contour.
Mains voltage is too
low.
Pressing tool is
defective.
Network failure
Action
▶ Repeat the pressing operation.
▶ Repeat the pressing operation.
▶ Only process permissible pressing
systems. → See "Intended use",
page 19.
▶ Repeat the pressing operation: press
the start button for at least 2 seconds.
▶ If this fault occurs several times in
succession, allow the pressing tool to
cool down completely.
▶ Clean the pressing jaw.
▶ Repeat the pressing operation.
▶ Check the mains voltage.
▶ Fully unreel the cable drum of the
extension cable.
▶ Reduce extension.
▶ Repeat the pressing operation.
▶ Check the pressfitting for tightness
and repeat the pressing operation if
necessary.
▶ Have the pressing tool inspected by
an authorised repair shop.
▶ Press the stop button: roller drive
moves to its starting position.
▶ Check the pressfitting for tightness
and repeat the pressing operation if
necessary.