Rated
Model
power [W]
IND90G5B8TRIC 11040 W
a) The appliance can be adjusted for different rated voltages, from 220-240 V (single-phase with 5 conductors) to 380-415 V
3N (three-phase with 5 conductors), but is equipped with a power cable only for 220-240 connection V (single-phase with 5
conductors).
The same 5x2.5 mm2 cable mounted in the factory for single-phase connection can be used for three-phase connection,
simply by moving the wire from 4 to 3, and removing the two jumpers between 1-2 and 2-3
b) Single-phase connection: 5-conductor power cable: 2 conductors for neutral, 2 conductors for 1 phase, 1 conductor for earth.
USABLE POWER CABLES
H05RR-F 5x2.5
H05VV-F 5x2.5
H05V2V2-F 5x2.5
H05RNF-F 5x2.5
H05SS-F 5x2.5
20
Rated Voltage
380-415 V 3N
380-400 V 3N
400-415 V 3N
380 V 3N
400 V 3N
415 V 3N
220-240/380-415 V 3N
220-230/380-400 V 3N
230-220/400-415 V 3N
220/380 V 3N
230/400 V 3N
240/415 V 3N
N
L
N N
L1 L1
220-240 V
220-230 V
230-240 V
220 V; 230 V; 240 V
---
Max 24 A (x2)
a)
b)
5 x 2.5 mm
2
N
L3
L2
L1
380-415 V 3N
380-400 V 3N
400-415 V 3N
380 V 3N; 400 V 3N; 415 V 3N
Max 16 A (x3)
5 x 2.5 mm2
Max 16 A (x3)
5 x 2.5 mm
2