C2. Use Top Cabinet Template For Preparation Of Top Cabinet; C3. Adapting Blower For Recirculation - Hisense HMO173SR Guía De Uso Y Cuidado

Ocultar thumbs Ver también para HMO173SR:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

C 2.
USE TOP CABINET TEMPLATE FOR PREPARATION OF TOP CABINET
You need to drill holes for
C 3.
ADAPTING BLOWER FOR RECIRCULATION
1.Remove and save screw that holds blower motor to microwave, Lift up the blower plate.
2.Carefully pull out the blower unit. The wires will extend far enough to allow you to adjust the blower unit.
B lower Motor
3.
Rotate blower unit 90°.
Before Rotation
Back of
Microwave
4. Place the blower unit back into the opening.
After Fan Blad
Openings Facing Front
5. Replace the blower plate in the same position.
Step-by-step installation guide
the top support screws
Back of
Microwave
Blower Plate screw
Blower motor screw
After
Back of
Microwave
and a hole large enough for the power cord to fit through.
• Read the instructions on the TOP CABINET TEMPLATE.
• Tape it underneath the top cabinet bottom.
• Drill the holes, following the instructions on the TO
CABINET TEMPLATE.
CAUTION : Wear safety goggles when
drilling holes in the cabinet bottom.
BEFORE : Fan Blade
Openings Facing UP
After
Back of
Microwave
CAUTION:
Do not pull or stretch the blower unit wiring.
Make sure the wires are not pinched.
NOTE:
The blower unit exhaust openings should match
exhaust openings on rear of microwave oven.