Outside Top Exhaust (Vertical Duct) Default; Attach Mounting Plate To The Wall - Hisense HMO173SR Guía De Uso Y Cuidado

Ocultar thumbs Ver también para HMO173SR:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

A.
OUTSIDE TOP EXHAUST (Vertical Duct ) DEFAULT
INSTALLATION OVERVIEW
.
A1
ATTACH THE MOUNTING PLATE TO THE WALL
A2.
USE TOP CABINET TEMPLATE FOR
PREPARATION OF TOP CABINET
A3.
CHECK FOR PROPER DAMPER OPERATION
A4.
MOUNT THE MICROWAVE OVEN
A5.
ADJUST THE EXHAUST ADAPTOR
A6.
CONNECTING DUCTWORK
A1.

ATTACH MOUNTING PLATE TO THE WALL

Attach the mounting plate to the wall using the wing nuts and machine screws (3/16" x 3").At least one
wood screw must be used to attach the mounting plate to a wall stud.
1.Insert the machine screws(3/16"X3") into the mounting plate through holes designed to go into drywall and
attach the toggle wings to ¾" onto each machine screw(3/16"X3").
2.Place the mounting plate against the wall and insert the toggle wings into the holes in the wall to mount the
plate.
CAUTION: Be careful to avoid pinching fingers between the back of the mounting plate and the wall.
3.Tighten all bolts. Pull the mounting plate away from the wall to help tighten the bolts.
14
Step-by-step installation guide
To use toggle bolts
Spacing for Toggles More
Than Wall Thickness
Wing nut
machine
Mountin
screw
Plate
Wall
Bolt End

Publicidad

Capítulos

Tabla de contenido
loading