13.2 - FUNCTION TABLE

DISPLAY
DATA
DESCRIPTION
dir
dX / SX
Gate direction (the direction you see from the inside)
P.APP
0 ÷ 100
Partial opening
t.PrE
0.5" ÷ 1.0'
Advance blinking time
no
t.PCh
0.5" ÷ 1.0'
Different closing pre-flashing time
no
vEL
3.5 ÷ 26.0
Speed during normal operation
vEL.r
3.5 ÷ 26.0
Speed during slowdown
rAM
0 ÷ 6
Starting ramp
FrEn
0 ÷ 10
Brake function
SEn.A
0.0A ÷ 9.9A
Enabling the AMPEROMETRIC obstacle sensor
SEn.v
0 ÷ 7
Enabling the SPEED obstacle sensor
rA.AP
0 ÷ 100
Slow down in opening
rA.Ch
0 ÷ 100
Slow down in closing
St.AP
Start during opening
PAUS
ChiU
no
St.Ch
Start during closure
Stop
APEr
St.PA
Start during pause
ChiU
no
PAUS
SPAP
Pedestrian start during opening
PAUS
ChiU
no
Ch.AU
Automatic reclosure
no
0.5"÷ 20.0'
Ch.tr
Closure after passage
no
0.5"÷ 20.0'
PA.tr
no/Si
Pause after passage
LUCi
Courtesy lights
t.LUC
no
CiCL
- Advance blinking disabled (corresponds to a value of 0)
- the closing pre-flashing time corresponds to t.PrE
- The gate pauses
- The gate recloses
- The START command is ignored
- The gate completes the cycle
- The gate reopens
- The gate recloses
- The START command is ignored
- The pause time is restarted (Ch.AU)
- The gate pauses
- The gate recloses
- The P. START command is ignored
- Automatic reclosure is not activated (corresponds to a value of 0)
- The gate recloses after the set period time
- Closure after passage disabled (load Ch.AU)
- The gate recloses after the set period time
- Timed function (from 0 to 20')
- Function deactivated
- On for the entire duration of the cycle
68
MEMO
DEFAULT
DATA
dx
25
1.0"
no
18
6
4
5
0.0A
3
15
15
PAUS
StoP
ChiU
PAUS
no
no
no
1'00