Bosch Rexroth SM24V Manual Del Usuario página 10

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 20
10/28 Bosch Rexroth AG | Electric Drives and Controls
13
25
Figure 2: SUB-D-Plug, 25pin (male)
Pin Signal
Description/
Function
1
24V
24-V-External
supply
2
E2
Input 2
3
E4
Input 4
4
E6
Input 6
5
E8
Input 8
6
E10
Input 10
7
A2
Output 2
8
A4
Output 4
9
A6
Output 6
10
A8
Output 8
11
A10
Output 10
12
A12
Output 12
13
0V
Reference
potential for
24 V
14
E1
Input 1
15
E3
Input 3
Table 2:
1
14
Voltage/Cur-
rent/Standard
24 V /
DIN19240
24 V /
DIN19240
24 V /
DIN19240
24 V /
DIN19240
24 V /
DIN19240
24 V /
DIN19240
24 V / 100 mA /
DIN19240
24 V / 100 mA /
DIN19240
24 V / 100 mA /
DIN19240
24 V / 100 mA /
DIN19240
24 V / 100 mA /
DIN19240
24 V / 100 mA /
DIN19240
24 V /
DIN19240
24 V /
DIN19240
SM24V | 3 609 929 725/1.2
Pin Signal
Description/
Function
16
E5
Input 5
17
E7
Input 7
18
E9
Input 9
19
A1
Output 1
20
A3
Output 3
21
A5
Output 5
22
A7
Output 7
23
A9
Output 9
24
A11
Output 11
25
A13
Output 13
Table 2:
(cont.)
BS300 operating system logically assigns
the tightening system's internal signals to the
respective inputs and outputs.
Voltage/Cur-
rent/Standard
24 V /
DIN19240
24 V /
DIN19240
24 V /
DIN19240
24 V / 100 mA /
DIN19240
24 V / 100 mA /
DIN19240
24 V / 100 mA /
DIN19240
24 V / 100 mA /
DIN19240
24 V / 100 mA /
DIN19240
24 V / 100 mA /
DIN19240
24 V / 100 mA /
DIN19240

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

3 609 929 725

Tabla de contenido