8/28 Bosch Rexroth AG | Electric Drives and Controls
1

Technical Data

Designation
Order number
Admissible ambient temperature
Admissible relative humidity when in operation
Admissible storage temperature
Admissible relative storage humidity
System of protection
Dimensions (B x H x T)
Weight
Table 1:
Subject to alteration
2

Intended Use

The SM24V interface module is intended to
be installed in the SE302 control unit or the
KE300 communications unit. The module en-
ables the tightening system to be controlled
via a 24V interface or for a 24V status signal
to be produced from the tightening system. In
addition, actuators and sensors can be con-
nected to this interface. Several modules can
be used in one tightening system. The corre-
sponding function is selected in the operat-
ing program.
The module has 10 inputs and 13 outputs
available. The outputs are short circuit-proof
and protected against polarity reversals.
SM24V conforms with DIN 19240.
3

Safety Notes

Please keep this Technical Information in a
place easily accessible for all users.
The Technical Information is intended for
specially trained personnel who have a spe-
cialized knowledge of the machine's hard-
ware components.
Repairs or other operations on the hardware
or software of our products, which are not de-
scribed in these instructions, may only be
carried out by Rexroth experts. Unqualified
SM24V | 3 609 929 725/1.2
SM24V
0 608 830 166
0 up to 55 °C with ventilator
20 - 90 % non-condensing
–20 °C up to 70 °C
20 - 95 %
IP 20 (~NEMA 1) when installed
24 mm x 81mm x 207 mm
0.05 kg
repairs or operations on the hardware or soft-
ware or the failure to observe the warnings in
these instructions or warnings placed on the
product itself could lead to personal damage
or damage to property.
Qualified personnel are:
– Project personnel, familiar with the safety
regulations of automation systems and
electrical engineering.
– Operators, instructed in the use of the
equipment and having knowledge of the
relevant operational parts of this docu-
mentation.
– Commissioning personnel authorized to
set electric circuits and machines/sys-
tems into operation, earth and mark them,
in accordance with the regulations of se-
curity technology.
Repairs and replacement of parts carried out
by the user are his own responsibility. After
repairing or replacing parts, all prescribed
functional and safety checks must be carried
out.