4

Assembly Instructions

The module is inserted into the system com-
ponents SE302/ KE300.
3 Min
Please take care that the interface module is
completely inserted.
The front knurled bolts must be tightened.
Please take care that the front blind fits close-
ly to the BT300.
Electric Drives and Controls | Bosch Rexroth AG 9/28
Before inserting the
Rexroth interface mod-
ules, the BT 300 card
rack must have been
voltage-free for at least
3 min.
5

Initial Operation

Before initial operation, the proper connec-
tion of all plugs must be checked.
Except for the jumper described below in
section 5.1, no other adjustment elements
are present.
5.1
Interface X 7.1
The interface is realised as a 25pin SUB-D-
plug. With the jumper on the board, it is pos-
sible to choose between internal and external
power supply for the outputs.
External
Extern
1)
Internal
Intern
Figure 1: SM24V, side view, jumper assignment for
internal/external power supply,
settings
In the setting "internal", the internal power is
used. In the setting "external", an external
power supply is used which must be con-
nected with Pin 1 (24 V) and Pin 13 (0 V).
If internal power is used, Pin 1 can be loaded
with a maximum of 500 mA.
1)
factory