Machine Components; Machine Setup - Tennant EX-SC-3840 Manual Del Operario

Aspirador para moquetas con depósito incorporado
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

OPERATION
EN

MACHINE COMPONENTS

7
10
9
11
8
1. Vacuum/Pump Switch
2. Brush/Spray Button
3. Brush Circuit Breaker (under switchbox)
4. Drain Hose
5. Accessory Tool Hookup
6. Recovery Tank Dome
7. Solution Tank Lid
8. Power Brush Head
9. Spray Bar
10. Brush Height Adjustment Knob
11. Pick Up Head
4
6
4
5
2
1
4
3
Home
Find... Go To..

MACHINE SETUP

1. Carefully check carton for signs of damage. Report
damages at once to carrier. The machine is
shipped fully assembled and is ready for use.
2. Remove solution tank lid. Using a hose or bucket, fill
tank with 38L (10 gal) of hot water, 60°C (140°F)
maximum (Figure 1).
NOTE: Use different buckets to fill and drain machine
to prevent solution system clogs.
FIG. 1
WARNING: Flammable materials can cause an
explosion or fire. Do not use flammable materials
in tank(s).
3. Add a recommended cleaning solution.
FOR SAFETY: When using machine, follow mixing
and handling instructions on chemical containers.
ATTENTION: If using powered cleaning chemicals,
mix prior to adding.
NOTE: If desired, water alone achieves excellent
cleaning results.
4. Replace lid securely after filling.
5. Connect extension cord to machine (120V model).
Plug cord into a grounded wall outlet (Figure 2).
Grounded
3 Hole Outlet
Ground Pin
(120V)
FIG. 2
EX- -SC- -3840 / EX- -SC- -3851 (04- -10)
Grounded Outlet
Grounding
Edge/hole
(220V/230V/240V)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ex-sc-38519007351900765490078199007490

Tabla de contenido