operation
The stove has two operational modes:
- manual:
In the MANUAL operational mode, the stove works on the
basis of the water temperature, read by the internal probe.
According to the water temperature the stove autonomously
modulates the working power so as to reach or maintain the
temperature of the water that has been set.
To select the MANUAL operational mode push the left lever
and set the desired room temperature (SET TEMP-ROOM)
over 40° C, by means of rotating the knob itself or using the +/-
keys. Confirmation is given with the ON/OFF keys.
To set the desired water temperature push the right lever and on
the display the words "SET WATER TEMPERATURE" will
appear.
To modify the set value, press and successively rotate the right
side knob or use the +/- keys.
Confirmation is given with the ON/OFF keys.
- automatic:
In the AUTOMATIC operational mode the stove works on the
basis of room temperature, read from the probe located on the
back right side.
According to the room, the stove autonomously modulates the
work power so as to reach or maintain the temperature of the
room that has been set.
To select the AUTOMATIC operational mode push the left
knob and set the desired room temperature (SET TEMP-
ROOM) UNDER 40° C, by means of rotating the knob itself
or using the +/- keys. Confirmation is given with the ON/OFF
keys.
Temperatures above 40° C will have the stove going to the
MANUAL operational mode, working on the basis of the water
temperature.
To set the desired room temperature push the left knob and on
the display the words "SET TEMP-ROOM" will appear.
To modify the set value, press and successively rotate the right
side knob or use the +/- keys.
Confirmation is given with the ON/OFF keys.
NOTE:
The default of the MANUAL/AUTOMATIC mode does not set
out that the stove carries out the shutdown phase upon reaching
the set temperature.
It is possible to have the STAND-BY function activated by
the Technical Assistant whohas carried out the 1st ignition and
who evaluated the installation of the stove in the water plant.
When the STAND-BY function is active, the stove carries out
the shutdown phase upon reaching the set temperature, to then
carry out the ignition phase (such function could wear out the
electrical resistance prematurely).
panel on/off button
Switches the stove on or off.
Within the menu, the On/Off button is used to return to the
previous menu or to exit the current mode.
panel +/- button
Increases or decreases the values that appear in the various
operating modes.
inStructionS for uSe
- 14
panel "reserve" button
Function to determine the amount of pellets remaining in the
hopper. This function can be enabled or disabled through the
user's menu, "reserve variation". If the "reserve" button is
pressed, a default value of 15kg will be added.
The value can be modified, accessing the "reserve variation"
user's menu; press the '+' or '-' buttons to increase
or decrease this value by a minimum of 5 Kg up to a maximum
of 15 Kg (if a value of 5 Kg is set, 5 Kg will
be added every time the "reserve" button is pressed).
In case of an error, press the '-' to go back.
panel
button
Informs the user of the stove's status; if pressed within the
menus it displays the previous menu/parameter.
LT knob
filling the feed ScreW
(only if the stove has no pellets)
To load the feed screw, access the USER'S MENU,
go to "INITIAL LOAD" and press the button.
This should only be done with the stove off and completely
cooled.
IGNITION
automatic ignition
With the stove on stand-by (with the word "TURNED OFF"
shown on the display), press the on/off button for 2 sec to start
the ignition process; the word 'IGNITION PHASE-PRELO-
ADING' (time during which the quantity of pellets necessary
for ignition is loaded ) is shown on the display followed by
'IGNITION PHASE' (time from which the glow plug is ignited
and the flame is detected) and then 'IGNITION PHASE-
WAIT FLAME' (time for which the stove awaits detection of
the flame).
When the flame is detected, the electrical resistance switches
off and the word "STABILIZATION" (time in which the stove
monitors the increase in smoke temperature, which must incre-
ase by no more than 2 degrees per minute otherwise an alarm is
triggered) appears on the display; once stabilization is complete
and all the tests are positive, the word "WORK" appears on the
display.
This procedure takes approximately 15 minutes.
Shutdown
By pressing the ON/OFF switch for 2 seconds while the stove
is functioning, the shutdown procedure starts (circulator in
operation, gear motor off, smoke extractor in operation) and the
message 'STOVE IN SHUTDOWN MODE' is visualised, this
procedure has a minimum duration of 15 minutes.
If the stove is blocked, see the alarms on page 14-15 or contact
your local dealer or Authorised Service Centre (CAT).
uSer'S menu
A 'USER MENU' is present on the display, the functions of
which can be explained by the Technical Assistance Centre that
started from the 1st ignition.
-
panel
RT knob