maintenance
cleaning the smoke duct
• With the boiler-stove off and cold, move the cleaning rods energetically (see page 18).
open the external pane, open the inspection hole of the left and right smoke pipes (fig. 5) and remove the residues (fig. 6).
the amount of residue will depend on the type of fuel and system.
failure to carry out this cleaning procedure may cause the thermal boiler-stove to block.
once the procedure iS implemented, enSure thatthe inSpection hatch iS
cloSed properly.
fig. 5
fig. 6
SeaSonal maintenance (implemented by the dealer)
Before performing any maintenance, disconnect the appliance from the mains.
The Dealer will provide you, on the occasion of the first start up, with the boiler-stove maintenance book, where the steps for
seasonal
cleaning, outlined here below, are listed.
• Clean the thermal boiler-stove internally and externally
• Carefully clean the heat exchange tubes
• Carefully clean and remove dirt from the combustion chamber and the relative compartment
• Clean the motors, verify mechanical and clam loosening
• Clean smoke channel (replace seals on pipes) and smoke extraction fan chamber
• Check the expansion tank
• Check and clean the circulator
• Check the sensors
• Check and if necessary replace the clock battery on the control board
• Clean, inspect and scrape any residue from the ignition resistance compartment and if necessary, replace it
• Clean/check the Synoptic Panel
• Visually inspect the electrical wires, connections and power cable
• Clean the pellet hopper and check loosening of the feed screw - gear motor assembly
• Check and if necessary replace the door seal
• Functionality test: load the feed screw, ignite, let it run for 10 minutes and shutdown
if maintenance if not implemented, the warranty will be rendered null and void.
if the thermal boiler-stove is used very often, it is recommended to clean the smoke channel every 3 months.
remember to vacuum the combuStion chamber before each ignition
Should ignition fail, do not re-ignite until you have emptied the combustion chamber.
attention: do not empty the reSidue
out into the pellet hopper.
- 19
-