Descargar Imprimir esta página

Farfisa HERO TD2000HE Manual Del Usuario página 16

Publicidad

is the one actually displayed (except when set on 255, you
can decide to give priority to viewing a camera whose address
is in one of the AUX CAM1 - AUX CAM8 locations above).
To program the priority camera address, select this item and
press key
; see paragraph Entering a numeric value to
learn how to enter addresses.
Video OFF
In this section you can program the first and last addresses
of two user groups that must not receive the video signal (for
example, only intercom users and any actuators that can be
enabled directly from the external station).
Press key
to display the items listed below and press key
to return to the previous menu.
- Video OFF-1-Start
- Video OFF-1-End
- Video OFF-2-Start
- Video OFF-2-End
Select the desired option from the four available ones and press
key
to set the block and the address, respectively, for the
first and last users in the first group and the first and last users
in the second group.
The following items will be displayed:
- Block
(255 by default.) System block to which the user belongs,
from 01 to 99; see paragraph Entering a numeric value to
learn how to enter addresses.
If the video intercom system is not to be used with block
splitting, leave it set on the default value.
- Address
(255 by default.) Allowed addresses: from 001 to 220. See
paragraph Entering a numeric value to learn how to enter
addresses.
Relay
The auxiliary relay can be assigned an actuator address (211-
220) or a user address (001-200) or set on address 255; de-
pending on the address stored, the auxiliary relay will behave
differently.
- Actuator address. By storing the address of an actuator,
that is a blocking address between 00 and 99 or address
255 and a device address between 211 and 220, the aux-
iliary relay will behave like an actuator and, when called, it
will be enabled with the mode set in the menu "System"
"Timings"
"Activate relay".
- User address. By storing a user's address, that is a block-
ing address between 00 and 99 or address 255 and a
user address between 001 and 200, the auxiliary relay
will be enabled only when a lock opening command arrives
from a user who has an address equal to or greater than
the one stored, instead of the S+/S- contact; if you store the
address 00-000, the auxiliary relay will be enabled when a
lock opening command arrives from any user instead of the
S+/S- contact, which will no longer be reachable from the
internal stations. The activation mode is the one set in the
menu "System"
"Timings"
- Address 255. By storing this address, the auxiliary relay
will be enabled when a lock opening command arrives at the
same time as an S+/S- activation. The activation mode is the
one set in the menu "System"
relay"
For programming, press key
and press key
to return to the previous menu.
- Block
(255 by default.) System block to which the user belongs,
from 01 to 99; see paragraph Entering a numeric value to
learn how to enter addresses.
If the video intercom system is not to be used with block
splitting, keep the default setting or enter 0.
- Address
(211 by default.) Allowed addresses are from 0 to 200, from
211 to 220 and 255. See paragraph Entering a numeric
value to learn how to enter addresses.
"Activate relay".
"Timings"
"Activate
to display the items below
Attention: To find users with addresses higher than the
one stored, the locking address must also be taken into ac-
count (for example, user 03-123 has an address above user
02-200).
Actuator1..Actuator4
(255 by default, not programmed.) You can store up to 4 ad-
dresses for DUO actuators in the system and can be enabled
by dialling one of the passwords stored in Users (address from
211 to 220). Actuators must be also programmed so that they
can be enabled from the external station. Press key
ter programming and press key
menu. See paragraph Entering a numeric value to learn how
to enter addresses.
Timings
In this section you can program the timing of system actuations.
Press key
to enter programming and press key
to the previous menu. Programming options:
- Activate S+S-: activation time of the lock opening circuit on
the external station (terminals S+ and S-).
- Activate relay: activation time of the auxiliary relay on the
external station (terminals C, NC and NO).
Use the
and
program and press key
Activate S+S-
(1 sec. by default) Press key
lowed values: 0 - 9 (0 contact disabled). See paragraph Enter-
ing a numeric value to learn how to enter the time.
Activate relay
(1 sec. by default) Press key
lowed values: 0 - 99 (0 bistable contact). See paragraph En-
tering a numeric value to learn how to enter the time.
PN parameters
When pressing any key connected to the PB/PB, P2 (J2) and
P3 (J3) inputs, you can associate the execution of one or more
actions. Press key
will be displayed:
- PB
- P2
- P3
Use the
and
program and press key
to return to the previous menu.
PB, P2, P3
In the PB or P2 or P3 menu, the following items will be listed:
- Actuations
- Time intervals
- Block
- Address
Use the
and
program and press key
- Actuations
(S+/S- for PB and P2; Relay for P3 by default.) This menu al-
lows you to associate one or more functions (maximum 9) to
be enabled when PB, P2 or P3 contacts are enabled. Func-
tions that can be associated:
- S+/S-: lock opening;
- Relay: auxiliary relay enabling;
- Actuator1, Actuator2, Actuator3, Actuator4: enabling of
up to 4 remote DUO actuators, if any, the addresses of which
have been set in the System/Addresses submenu;
- Ring-me: when the password is entered correctly, the user
whose address is stated in the subsequent Block and Ad-
dress fields will ring one time;
- Call: a call is made to the user stated in the subsequent Block
to return to the previous
arrows to select the function you want to
to confirm your selection.
to enter programming. Al-
to enter programming. Al-
to enter the menu and the following items
arrows to select the function you want to
to confirm your selection. Press key
arrows to select the function you want to
to confirm your selection.
to en-
to return
Mi 2565
- 16 -

Publicidad

loading

Este manual también es adecuado para: