Descargar Imprimir esta página

dirna Bergstrom Bycool COMPACT 1.4 Diagnosis De Averías página 19

Ocultar thumbs Ver también para Bycool COMPACT 1.4:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 6
COMPACT 1.4
• Connect or replace the power cable fuse.
• Replace electronic control (to access, remove the access cover on the electronic control
located on the inner air distribution panel).
• Check and correct possible bad contacts, breakages or disconnection of the power cable.
• Connect or replace the electronic control power supply fuse (to access, remove the
access cover on the electronic control located on the inner air distribution panel).
• Check and correct the position of the connection cables to power supply (Az with 25A fuse
a + and M a -).
!
(If the error persists contact an Authorised Service Centre).
• Check and correct possible bad contacts on terminals or cables of the return air probe.
• Connect or replace return air probe.
!
(If the error persists contact an Authorised Service Centre).
• Check and correct possible bad contacts on connections or terminals of the power cable.
• Charge or replace the battery.
!
(If the error persists contact an Authorised Service Centre).
Solution
19
EN
®

Publicidad

loading