Symptom
• E2 appears on the display, the device
turns off automatically and the display
E2 until the fault is
shows error
repaired. To remove it from the display
press the ON/OFF key once on the
control panel or the remote control.
• One of both compressors do not
work.
• The device does not respond to the
remote control.
• Centrifugal blower or condenser fan blocked in
short circuit or disconnected.
• 7.5A fuse in the centrifugal blower or condenser
fan blown.
• Electronic control faulty.
• Bad connection of the terminals.
• Electronic module/s on the compressor/s
faulty.
• Compressor/s faulty.
• Too much pressure in the circuit due to excess
load or very high temperature.
• Control deprogrammed.
• Control battery empty, the LED does not light
up.
• Electronic control faulty.
• Control faulty.