INSTALLATION STEP 9
Attach the Emergency Release Rope
and Handle
• Thread one end of the rope through the hole in the top
of the red handle so "NOTICE" reads right side up as
shown. Secure with an overhand knot at least 1"
(2.5 cm) from the end of the rope to prevent slipping.
• Thread the other end of the rope through the hole in the
release arm of the outer trolley.
• Adjust rope length so the handle is 6 feet (1.8 m) above
the fl oor. Ensure that the rope and handle clear the tops
of all vehicles to avoid entanglement. Secure with an
overhand knot.
NOTE: If it is necessary to cut the rope, heat seal the cut
end with a match or lighter to prevent unraveling.
INSTALLATION STEP 10

Electrical Requirements

To avoid installation diffi culties, do not run the opener
at this time.
To reduce the risk of electric shock, your garage door
opener has a grounding type plug with a third grounding
pin. This plug will only fi t into a grounding type outlet.
If the plug doesn't fi t into the outlet you have, contact a
qualifi ed electrician to install the proper outlet.
RIGHT
If permanent wiring is required by your local code, refer
to the following procedure.
To make a permanent connection through the 7/8" hole in
the top of the motor unit:
• Remove the motor unit cover screws and set the cover
aside.
• Remove the attached 3-prong cord.
• Connect the black (line) wire to the screw on the brass
terminal; the white (neutral) wire to the screw on
the silver terminal; and the ground wire to the green
ground screw. The opener must be grounded.
• Reinstall the cover.
To avoid installation diffi culties, do not run the opener at
this time.
WRONG
To prevent possible SERIOUS INJURY or DEATH from
a falling garage door:
• If possible, use emergency release handle to
disengage trolley ONLY when garage door is
CLOSED. Weak or broken springs or unbalanced
door could result in an open door falling rapidly
and/or unexpectedly.
• NEVER use emergency release handle unless garage
doorway is clear of persons and obstructions.
• NEVER use handle to pull door open or closed. If
rope knot becomes untied, you could fall.
Trolley
Release Arm
Emergency
Release Handle
To prevent possible SERIOUS INJURY or DEATH from
electrocution or fi re:
• Disconnect ALL electric and battery power BEFORE
performing ANY service or maintenance.
• Garage door installation and wiring MUST be
in compliance with ALL local electrical and
building codes.
• NEVER use an extension cord, 2-wire adapter, or
change plug in ANY way to make it fi t outlet. Be
sure the opener is grounded.
PERMANENT WIRING
CONNECTION
Ground Tab
Green
Ground
Screw
Ground Wire
White Wire
18
Trolley
Overhand
Knot
Black
Wire
White Wire
Black
Wire